Gage,Pressure,Transducers,Validyne,P2

Gage Pressure
Transducers Validyne P2


   Products

 Analytical

 Flow

 Gas Detection

 
Level

 Panel Instruments

 Pressure

 Process Controllers

 Temperature

 Valve Control

 
Contact Us

 
www.cancoppas.com





  Gage Pressure Transducers Validyne P2

Model P2 - Low Cost Gage Pressure Transducers

Model P2 Gage Pressure Transducers Description

Validyne's new Model P2 Gage Pressure Transducers provide a low cost solution for pressure measurement in a wide variety of industrial and OEM applications. With a rugged design and stainless steel wetted parts, Model P2 Gage Pressure Transducers feature superior performance at a reasonable price. Units are offered with a high level output of 4 to 20 mA or 0 to 5 Vdc.

The Model P2 Gage Pressure Transducers has a standard 1/4" male pipe thread connection, and comes with a mating DIN electrical connector for fast wiring. Model P2 Gage Pressure Transducers superior performance is assured through the use of chemical vapor deposition strain gage technology. Sensors are produced on wafers in large batches by depositing silicon dioxide and polysilicon on a stainless steel substrate, resulting in a strong, reliable design. The Model P2 Gage Pressure Transducers are accurate to 0.25% and have excellent long term stabiity. They resist shock and vibration and are compensated for -4 to +176 F ambient environments.

Applications for the Model P2 Gage Pressure Transducers include:

  • Pumps and Compressors

  • Hydraulic Systems

  • Refrigeration

  • Pneumatic Systems

Model P2 Gage Pressure Transducers Specification Summary

Available Pressure Ranges:
  • 0-15 psig
  • 0-30 psig
  • 0-60 psig
  • 0-100 psig
  • 0-200 psig
  • 0-500 psig
  • 0-1000 psig
  • 0-3000 psig
  • 0-5000 psig
Signal Output: 4-20 mA or 0.1-5V
Power Required:

24 Vdc nominal
4-20 mA Output: 12-36 Vdc
0.1 - 5V Output: 7.5 to 30 Vdc
Pressure Port:
1/4" NPT Male
Proof Pressure:

2x Operating Press <= 3000 psi;
1.5x Operating Pressure > 3000 psi
Burst Pressure:
5x Operating Pressure, minimum
Fatigue Life:
100 Million Cycles
Error Band:
+/-0.25% span, including Non-linearity, Hysteresis and Non-repeatability
Compensated Temp Range:
-4 to +176ºF
Thermal Error Band: +/-1.5% Span over Compensated Temperature Range
Vibration:
35g Peak Sinusoidal; 5 to 2000 Hz
Isolation:
100 MOhms @ 50 Vdc
Enclosure:
NEMA 4
Wetted Material:
17-4 PH Stainless Steel, Nickel Braze
Weight:
3.5 Oz, max
Stability:
0.2% Span over 1 year



Gage Pressure
Transducers Validyne P2