  Model P365 High Line - Differential Pressure Transmitter

P365 Differential Pressure Transmitter Description

The Validyne Model P365 Differential Pressure Transmitter is a compact high line, differential pressure transmitter designed for industrial measurement applications. The variable reluctance sensing technology allows the P365 to be used in a wide variety of low differential pressure measurements at high static line pressures with a minimum of zero shift. In addition, the Model P365 Differential Pressure Transmitter has high resistance to vibration and superior signal stability through ambient temperature change. The P365 will accept liquids and gases directly at the sensing diaphragm; there are no internal fill fluids to slow the sensor response or cause excessive temperature shift.

The Model P365 Differential Pressure Transmitter is available in three output configurations: 4-20 mA current sink, +/-5 Vdc and isolated +/-5 Vdc outputs. The 4-20 mA output is a true two-wire system and will operate over any power supply from 9-55 Vdc.

The Model P365 Differential Pressure Transmitter can measure full scale differential pressures as low as +/-5 psid at static line pressures as high as 10Kpsi. Zero and span controls are available for external adjustment, and the wiring may be via connector or pigtail leads options. The Model P365 Differential Pressure Transmitter housing is rated NEMA 4.

Applications for the Model P365 Differential Pressure Transmitter Include:

  • Hydraulic Flow and Pressure Measurement

  • Vehicle Brake Testing

  • Oilfield Core Permeability Testing

Model P365 Differential Pressure Transmitter Specification Summary

Ranges: +/-5.0 psid FS to +/-10,000 psid FS
Accuracy: +/-0.5% FS, incl Non-Linearity, Hysteresis and Non-Repeatability (1% FS for ranges above 5Kpsid)
Overpressure: 200% FS up to 12.5Kpsi max
Line Pressure: to 12500 psig maximum
Line Pressure Effect: 1% FS/1000 psi, 3% FS maximum total
Pressure Ports: 5/16-24 UNJF-3B
Temperature Range: 0ºF to 160ºF, standard
Temperature Error: +/-2%/100F FS
Pressure Media: Liquids and gases compatible with 410 SST and selected O-Ring
O-Rings: Buna-N Standard, others optional
Power Required: 9 to 55 Vdc
Signal Output: 4 to 20 mA and +/-5 Vdc Versions Available
Frequency Response: 250 Hz Low Pass Filter
Isolation Option: 100 MOhms @ 500 Vdc
Electrical Connections: Bendix PT02A-10-6P Connector or 24 inch Pigtail leads, 16 gauge with 1/2 inch NPT conduit connection