Infrared Thermometers Linear C-1000 Series |
| Advanced
User Interface & Easy To Use
The Linear C-1000 Series Infrared Thermometers are self-contained, battery-operated devices for non-contact temperature measurement. Each unit consists of a probe and a display unit. The probe unit easily attaches to the display unit for single hand operation. The power source is a single 9-Volt alkaline battery. The C-1000P is supplied with an external power jack and an analog output jack which are located on the side of the display unit. |
|
The Linear C-1000 Series Infrared Thermometers utilize a passive sensor which receives and measures infrared radiation from an object. Since temperature is measured without contact, heat is not removed from the measured object. Therefore accuracy of the reading is assured. Measurements are more rapidly (less than one second) so that thermal patterns and transient phenomena can be observed. Moving objects, dangerous materials, process steps, and operating electrical components can be safely and effectively measured. The C-1000 is ideal for taking and storing readings during Preventive Maintenance checks on several pieces of equipment. |
Features
|
| The Linear C-1000 Series
Infrared Thermometers uses a Liquid Crystal Display to enter commands
and display data. This innovation greatly simplifies the operation of
the product. A two position switch located on the left side of the display
unit is used to select POWER ON and OFF. A new technology liquid crystal
display runs the full length of the front of the display unit. This technology
allows the user to easily identify the system mode as the mode switch
changes colors when selected. With the exception of turning on the power,
all functions are controlled by touching the appropriate position on the
display.
The C-1000 System contains nonvolatile memory. The nonvolatile memory feature allows the system to remember previous settings upon power up. Measurements can be made from a distance as close as ¼ inch (0.6 cm). As the distance to the source is increased, the diameter of the measured area increases proportionally. For the C-1000 at 3 inches (7.6 cm) the measured area is about 1 inch (2.5 cm) in diameter. The analog output signal is 1 millivolt per degree. This signal is often useful in further troubleshooting process related problems. |
| Typical
Applications Non-Destructive Testing
|
Floor
Covering
|
Paper
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Accessories C-WAND - Used
to maintain a constant distance between the probe and the target. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||