Linear,Laboratories,MX-HT,Series,Specifications


Linear Laboratories MX-HT Series Specifications

Preliminary MX-HT Specification Sheet

Outputs:

Type R Thermocouple
Type S Thermocouple
Type B Thermocouple
1 mV/degree (F or C)
0-5 Volts
4-20 mA
0-20 mA
RS-232 Serial Digital
RS-485 Serial Digital

Temperature Range:

1500-3000° F
800-1600° C

Wavelength: .85 to .95 Micron

Input Power: 9-30 VDC, 50 mA 120 VAC with adapter

Accuracy: ± 1% of reading, ± 2° F (± 1° C)

Repeatability: ± 0.5% of reading, ± 1 digit

Response time: 300 milliseconds

Distance to Target Ratio:

50:1 (Minimum Target ¼" @ 15")
75:1 (Minimum Target ¼" @ 18")

Emissivity:

0.10 to 0.99 in .01 digital steps

Ambient Temperature:

Sensing Head: 0 to 150° F non-condensing
(With optional cooling: 0 to 350° F)
Signal Processor: 0 to 120° F

Environmental:

NEMA-4 (IECS529, IP65)

Connections:

15’ (4.6m) of detachable cable

Dimensions:

Sensing Head: 5.3" long x 1.63" dia, 1.5-20 thread
Signal Processor: 5.25" x 3.62"
Optional NEMA-4, 12: Enclosure 6" x 4" x 3"

Weight:

Sensing Head: 9 oz.
Signal Processor: 4 oz.
NEMA Box: 43.2 oz.


( Back )



Linear Laboratories MX-HT Series Specifications

Site Designed By Panther Marketing & Design