| Activated Carbon
- The MP 55 liquid adsorbers are filled with virgin,
high activity GC 8x30 carbon. Virgin GC 12x40, reactivated
GC 8x30R or other special carbons are also available.
Removable Dished
Head - The removable lid is held in place
with 20 stainless steel bolts through steel reinforced
flanges. The gasket is made of 3/16 " thick neoprene.
Connections
- Metal connections with standard pipe threads
insure easy, durable, and leak proof hookup to
your system. Unions or quick connect fittings
are advised to make vessel exchange easy.
Flow Distributors
- Both inlet and outlet have low pressure drop,
slotted Schedule 40 PVC distributors. Units are
designed to work downflow. Stainless steel internals
are available for special applications.
Coatings
- The MP 55 is coated with coal tar epoxy on the
inside and a 2-part epoxy on the outside.
Installation
& Start Up - If possible before the
units are used for the first time, they should
be filled with clean water for a period of 8 to
12 hours to allow the carbon to degas. A gentle
backwash is also recommended to remove carbon
fines that can cause excessive pressure drop through
the unit. Multiple units are usually connected
in series with testing between the units advised
to determine when the first unit needs to be changed
out.
Maintenance
- Once connected, The MP 55 requires no maintenance
other than the monitoring of the influent and
effluent liquid streams and the operating pressure
of the system. Monitoring the liquid stream into
the last unit in series mode is a recommended
safeguard against breakthrough in the final outflow.
When the concentration of contaminants in the
outflow equals the concentration in the inflow,
The MP 55 has reached its removal capacity and
should be removed from service. The working life
of each adsorber is dependent upon the type of
contaminant in the water as well as its concentration
and the liquid flow rate. A pressure relief device
is advised to prevent damage to the vessel in
the event of excessive pressure buildup.
Recharging
- Once the carbon is saturated by contaminants,
the unit should be removed and replaced with a
fresh one. To purchase replacement carbon or to
arrange for a carbon change-out, please contact
our office.
Disposal
- Dispose of the spent carbon in accordance with
Federal, State, and Local regulations
Caution!
Wet activated carbon removes oxygen from air causing
a severe hazard to workers inside carbon vessels.
Confined space/low oxygen procedures should be
put in place before any entry is made. Such procedures
should comply with all applicable local, state
and federal guidelines.
|