Calibration,Cylinders,Kenco,Engineering

Calibration Cylinders
from Kenco Engineering

 
 
 
 
 
Calibration Cylinders from Kenco Engineering

Calibration Cylinders Applications

  • To calibrate the flow rate of chemical metering pumps and chemical injection systems
  • To periodically monitor the performance and accuracy of a chemical injection system
  • To insert accurate dosages of chemical into batch processes
Calibration Cylinders Features
  • Dual Scale:
  • - 1. Total gauge volume in millimeters
  • - 2. Gallons per hour scale for a one minute test of calibration to determine flow rate
  • Models with threaded NPT connections on both ends and models with removable slip on caps available
  • Mylar laminated scales are protected form attack bu harsh chemicals
  • Rugged construction using transparent PVC pipe and industrial grade PVC fittings
  • Special sizes available upon request
  • Other materials also available

Installation And Operating Instructions for Calibration Cylinders

  • 1. To test the pump rate of the chemical pump, open valve B and fill the gauge to the top division mark.
  • 2. When the fluid level reaches the top mark, close valve A and at the same time, begin timing the test.
  • 3. After one minute, observe the level of fluid in the column.
  • 4. The change in level after one minute is the actual pump rate of the chemical pump.
  • 5. When the gauge is not in use, valve B must be closed.
  • 6. Valve A must remain open at all times except when the user is testing the pump rate.

Calibration Cylinders
from Kenco Engineering


Site Designed And Maintained By Panther Marketing And Design