Purpose
Of LCE Oil Level Controllers
The KENCO LCE utilizes
the operating principles of both the oil level controller and
the electric switch.
LCE Oil Level Controllers
Applications
Hazardous locations
where flameable or combustable elements are present.
LCE Oil Level Controllers
Materials Of Construction
-
Valve Seat -
Nitrile
-
Optional Valve
Seat Material - Fluorocarbon
-
Valve Orifice
- Aluminum
-
Housing - Aluminum
-
Float Material
- Closed Cell Polyurethane
-
Oil Inlet Screen
- 20 Mesh Brass Cloth
-
Sight Window
- Clear Polycarbonate (UV Stabilized)
LCE Oil Level Controllers
Oil Inlet Specifications
LCE Oil Level
Controllers Flow Rate Test Results
| Low Pressure Tested at
32 º F with SAE 30
2' head = 1.1413 GPH
4' head = 2.122 GPH
7' head = 2.853 GPH
12' head = 3.043 GPH
|
| High Pressure
Tested at 20 º F with SAE 30
5 PSI = 0.163 GPH
20 PSI = 0.2655 GPH
|
LCE Oil Level
Controllers Electric Switch Specifications
- Switch trip point: 3/4"
drop
- Switch Rating -
- 15 amp, 125/250/480
VAC
- 0.5 amp, 125 VDC
- 0.25 amp, 250 VDC
- 1/8 hp, 125 VDC
- 1/4 hp, 250 VAC
- Circuitry SPDT
- Maximum Temperature:
180of / 82oC
- Electrical Connection:
1/2" FNPT
- CSA Approved for Class
1, Div. 1, Div. 2,
- Group C and D Hazardous
locations
- SPDT standard, DPDT
available
- High Level Switch available
|
LCE Oil Level Controllers
Shipping Weight
7.5
lbs.