Purpose Of LCM
Oil Level Controllers
The KENCO LCM utilizes
the operating principles of both the oil level controller and
the electric switch. The LCM is intrinsically safe when used with
an approved safty barrier.
LCM Oil Level Controllers
Applications
Intrinsically safe
applications with an approved safty barrier.
LCM Oil Level Controllers
Materials Of
Construction
- Valve Seat - Nitrile
- Optional Valve Seat Material
- Fluorocarbon
- Valve Orifice - Aluminum
- Housing - Aluminum
- Float Material - Closed Cell
Polyurethane
- Oil Inlet Screen - 20 Mesh
Brass Cloth
- Sight Window - Clear Polycarbonate
(UV Stabilized)
- Switch Test Button Standart
LCM Oil Level Controllers
Wire Color Code
- Red: Normally Closed
- Blue: Normally Open
- White: Common
|
LCM Oil Level Controllers
Oil Inlet Specifications
LCM Oil Level
Controllers Flow Rate Test Results
| Low Pressure Tested at
32 º F with SAE 30
2' head = 1.1413 GPH
4' head = 2.122 GPH
7' head = 2.853 GPH
12' head = 3.043 GPH
|
| High Pressure
Tested at 20 º F with SAE 30
5 PSI = 0.163 GPH
20 PSI = 0.2655 GPH
|
LCM Oil Level Controllers Electric Switch Specifications
- Switch trip point: 3/4"
drop
- Switch Rating -
- 10 amp, 125/250 VAC
or VDC
- Circuitry SPDT
- Maximum Temperature:
180of / 82oC
- Electrical Connection:
1/2" FNPT
- Wire Leads; 18 AWG x
24" long
|
LCM Oil Level Controllers
Shipping Weight
7
lbs.