Purpose Of LCP Oil Level Controller
The
KENCO LCP utilizes the operating principles of both the oil level
controller and the electric switch.
LCP Oil Level Controller
Applications
Remote
or offshore locations with no electric power.
LCP Oil Level Controller
Materials Of
Construction
- Valve Seat - Nitrile
- Optional Valve Seat Material
- Fluorocarbon
- Valve Orifice - Aluminum
- Housing - Aluminum
- Float Material - Closed Cell
Polyurethane
- Oil Inlet Screen - 20 Mesh
Brass Cloth
- Sight Window - Clear Polycarbonate
(UV Stabilized)
LCP Oil Level Controller
Oil Inlet Specifications
LCP Oil Level
Controller Flow Rate Test Results
| Low Pressure Tested at
32 º F with SAE 30
2' head = 1.1413 GPH
4' head = 2.122 GPH
7' head = 2.853 GPH
12' head = 3.043 GPH
|
| High Pressure
Tested at 20 º F with SAE 30
5 PSI = 0.163 GPH
20 PSI = 0.266 GPH
|
LCP Oil Level Controller Pneumatic Switch Specifications
- Switch trip point: 3/4"
drop
- Maximum Air Valve Inlet
Pressure - 100 psi
- Switch Test Button Standard
- Air Inlet Connection:
1/4" FNPT
- Maximum Temperature:
180of / 82oC
|
LCP Oil Level Controller
Shipping Weight
6.5
lbs.