Pump,Setting,Gauges,Calibrating,Chemical,Pumps

Pump Setting Gauges for
Calibrating Chemical Pumps

 
 
 
 
 
Pump Setting Gauges For Calibrating Chemical Pumps

Pump Setting Gauges Equipment Features

  • Maximum Static Head Pressure (Must be shielded if there is any pressure present in system).

  • Pyrex Gauge Cylinder is standard. Plastic tubing may be substituted.

  • Fluorocarbon o-ring seals are standard. Other elastomers are available.

  • Gauge Glass Repair Kits include calibrated scale to insure gauge accuracy.

  • Gauges are available with (6) standard options on scale calibration units (GPH, LPH, GPD, LPD, GBV, &  LBV).










Pump Setting Gauges Specifications

        A B
Gauge Model Number Maximum Pump Rate Scale Units Based on a 1 Min Test Inlet Port Size CS/SS End Plates PVC/
CPVC End Plates
Standard/
Lexan Shield
Metal Guard *Glass Repair Kit
30016 16 GPD .5 GPD 1/4" NPT 16-1/4" 16-1/2" 2-1/2" 3-1/2" 30016-RK
30030 30 GPD 1 GPD 1/4" NPT 12-7/8" 13-3/8" 2-1/2" 3-1/2" 30030-RK
30060 60 GPD 1 GPD 1/2" NPT 14-15/16" 15-7/16" 2-1/2" 3-1/2" 30060-RK
30096 96 GPD 2 GPD 1/2" NPT 14-15/16" 15-7/16" 2-1/2" 3-1/2" 30096-RK
30144 144 GPD 5 GPD 1/4" NPT 12-7/8" 13-3/8" 3" 4" 30144-RK
30216 216 GPD 5 GPD 1/2" NPT 12-7/8" 13-3/8" 3-1/2" 4-1/2" 30216-RK
30280 280 GPD 5 GPD 1/2" NPT 12-7/8" 13-3/8" 3-1/2" 4-1/2" 30280-RK
30420 420 GPD 10 GPD 1/2" NPT 12-7/8" 13-3/8" 4" 5" 30420-RK
30580 580 GPD 10 GPD 3/4" NPT 12-7/8" 13-3/8" 4-1/2" 5-1/2" 30580-RK
30700 700 GPD 20 GPD 3/4" NPT 12-7/8" 13-3/8" 5" 6" 30700-RK
31440 1440 GPD 25 GPD 1" NPT 14-3/8" 14-3/8" 7" 8" 31440-RK

*REPAIR KIT: Add suffix -V-GPH to glass repair kit part number for O-Ring seal material and scale units required. See gauge ordering information below for O-Ring seal/scale units available.

GAUGE MODEL NUMBER/ORDERING INFORMATION

GAUGE MODEL NUMBER END PLATE MATERIAL O-RING SEAL MATERIAL SCALE UNITS SIGHT TUBE SHIELD OPTIONS
See

chart

above

CS
(Carbon Steel)
S4
(304 Stainless Steel)
S6
(316 Stainless Steel)
P
(Polyvinyl Chloride)
C
(Chlorinated Polyvinyl Chloride)
A
(Aflas)
B
(Buna-N)
EP
(Ethylene Propylene)
TES
(Teflon Encapsulated Silicone)
V
(Flourocarbon)
GPH
(Gallons Per Hour)
LPH
(Liters Per Hour)
GPD
(Gallons Per Day)
LPD
(Liters Per Day)
GBV
(Gallons By Volume)
LBV
(Liters By Volume)
S
(Standard/No Shield)
LS
(Lexan Shield)
GG
(Expanded Metal Guard)

SCALE UNITS: Rate scale units are based on a one minute test
MODEL NUMBER EXAMPLE: 30016-CS-V-GPD-S

Pump Setting Gauges for
Calibrating Chemical Pumps


Site Designed And Maintained By Panther Marketing And Design