EchoTouch,Three Wire,Ultrasonic Level Transmitter,Flowline

EchoTouch™ Three Wire Ultrasonic Level Transmitter



EchoTouch™ Three Wire Ultrasonic Level Transmitter
LU_0-_0_ _
 
 
 
Application
The general purpose three-wire ultrasonic transmitter provides non-contact level measurement up to 40' or 12.2 m with an internal relay that can be configured as a single-point alarm or latched on two points for automatic fill or empty control. The transmitter is ideally suited for challenging corrosive, slurry or waste liquids and is typically selected for large atmospheric bulk storage and waste sump applications. Media examples include sulfuric acid and resin.
Specifications
Range:
2" mount: 0.5' to 24.5' (15 cm to 7.4m)
3" mount: 1.5' to 40' (46 cm to 12.2m)
Accuracy:
± 0.25% of span in air
Resolution:
0.125" (3 mm)
Beam width:
8° conical
Dead band:
LU30: 0.5' (15 cm)
LU50: 1.5' (50 cm)
Display type:
LED, 4-digit
Display units:
Inch or cm
Memory:
Non-volatile
Supply voltage:
14-36 VDC
Consumption:
200 mA max.
Current flow:
Source/sink
Signal output:
4-20 mA, three-wire
Signal invert:
4-20 or 20-4 mA
Calibration:
Digital, push button
Contact type:
(1) SPDT relay, latching
Contact rating:
250 VAC @ 10A
Contact logic:
Single point: alarm
Two point: latching
Contact fail-safety:
Reverts to safe state during echo-loss
LED indication:
Relay status
Process temp.:
F: -40° to 140°
C: -40° to 60°
Temp. comp.:
Automatic
Electronics temp.:
F: -20° to 140°
C: -4° to 60°
Pressure:
30 psi (2 bar) @ 25° C.,
derated @ 1.667 psi (0.113 bar)
per °C. above 25° C.
Enclosure rating:
NEMA 4X (IP65)
Installed height:
LU30: 5.1" (13 cm)
LU50: 10.6" (26.9" cm)
Encl. material:
PP, UL94VO
Trans. material:
2" mount: PVDF Kynar®
3" mount: Polyvinylchloride
Cable jacket mat.:
Vinyl
Cable type:
Pow./signal: 3-conductor
Relay: 3-conductor
Cable length:
3' (91 cm)
Process mount:
2" NPT (2" G): 24.5' (7.4m)
3" ANSI/DIN 80 flange:
40' (12.2m)
Mount. gasket:
Viton® (2" G version only)
Conduit entrance:
Single, 1/2" NPT
Classification:
General purpose
CE compliance:
EN 50082-2 immunity
EN 55011 emission
EN 61010-1 safety
Click here to download above specifications in a PDF file format.

Click here to download above Manual in a PDF file format.
 
Technology
ULTRASONIC
General purpose Yes
Integral relay Yes
Conductive Yes
Non-conductive Yes
Conductivity Yes
Non-contact Yes
Clean Yes
Dirty Yes
Coating Yes
Non-coating Yes
Ambient pressure Yes
Low pressure Yes
Intrinsically safe No
Medium pressure No
Foam No
Contact No
Vapors No
Gas density No
Vacuum No