LU_0-_0_ _ |
 |
|
|
|
|
|
|
Application |
| The general purpose three-wire ultrasonic transmitter provides non-contact level measurement up to 40' or 12.2 m with an internal relay that can be configured as a single-point alarm or latched on two points for automatic fill or empty control. The transmitter is ideally suited for challenging corrosive, slurry or waste liquids and is typically selected for large atmospheric bulk storage and waste sump applications. Media examples include sulfuric acid and resin.
|
|
|
|
Specifications |
|
Range:
|
2" mount: 0.5' to 24.5' (15 cm to 7.4m)
3" mount: 1.5' to 40' (46 cm to 12.2m) |
|
Accuracy:
|
± 0.25% of span in air |
|
Resolution:
|
0.125" (3 mm) |
|
Beam width:
|
8° conical |
|
Dead band:
|
LU30: 0.5' (15 cm)
LU50: 1.5' (50 cm) |
|
Display type:
|
LED, 4-digit |
|
Display units:
|
Inch or cm |
|
Memory:
|
Non-volatile |
|
Supply voltage:
|
14-36 VDC |
|
Consumption:
|
200 mA max. |
|
Current flow:
|
Source/sink |
|
Signal output:
|
4-20 mA, three-wire |
|
Signal invert:
|
4-20 or 20-4 mA |
|
Calibration:
|
Digital, push button |
|
Contact type:
|
(1) SPDT relay, latching |
|
Contact rating:
|
250 VAC @ 10A |
|
Contact logic:
|
Single point: alarm
Two point: latching |
|
Contact fail-safety:
|
Reverts to safe state during echo-loss |
|
LED indication:
|
Relay status |
|
Process temp.:
|
F: -40° to 140°
C: -40° to 60° |
|
Temp. comp.:
|
Automatic |
|
Electronics temp.:
|
F: -20° to 140°
C: -4° to 60° |
|
Pressure:
|
30 psi (2 bar) @ 25° C.,
derated @ 1.667 psi (0.113 bar)
per °C. above 25° C. |
|
Enclosure rating:
|
NEMA 4X (IP65) |
|
Installed height:
|
LU30: 5.1" (13 cm)
LU50: 10.6" (26.9" cm) |
|
Encl. material:
|
PP, UL94VO |
|
Trans. material:
|
2" mount: PVDF Kynar®
3" mount: Polyvinylchloride |
|
Cable jacket mat.:
|
Vinyl |
|
Cable type:
|
Pow./signal: 3-conductor
Relay: 3-conductor |
|
Cable length:
|
3' (91 cm) |
|
Process mount:
|
2" NPT (2" G): 24.5' (7.4m)
3" ANSI/DIN 80 flange:
40' (12.2m) |
|
Mount. gasket:
|
Viton® (2" G version only) |
|
Conduit entrance:
|
Single, 1/2" NPT |
|
Classification:
|
General purpose |
|
CE compliance:
|
EN 50082-2 immunity
EN 55011 emission
EN 61010-1 safety |
|
Click here to download above specifications in a PDF file format.
Click here to download above Manual in a PDF file format. |
|
|
|
|
|
Technology |
|
ULTRASONIC |
|
General purpose |
Yes |
|
Integral relay |
Yes |
|
Conductive |
Yes |
|
Non-conductive |
Yes |
|
Conductivity |
Yes |
|
Non-contact |
Yes |
|
Clean |
Yes |
|
Dirty |
Yes |
|
Coating |
Yes |
|
Non-coating |
Yes |
|
Ambient pressure |
Yes |
|
Low pressure |
Yes |
|
Intrinsically safe |
No |
|
Medium pressure |
No |
|
Foam |
No |
|
Contact |
No |
|
Vapors |
No |
|
Gas density |
No |
|
Vacuum |
No |
|
|
|