Technology
Unique I AM WORKING
function
The One Series provides a continuous indication of its health AND the
switch output status, both locally and remotely. An LED on the front panel
and a discrete logic output signal are used to communicate three states:
- I AM WORKING but I Have Not Switched
- I AM WORKING and I Have Switched
- I Am Not Working
The One Series I AM WORKING feature
diagnoses the health of the sensor, software, microprocessor and power
supply. And it does all this on a continuous basis. Used in conjunction
with the standard switch output, the I AM WORKING signal
can even help satisfy many DPDT requirements. Functions of the I AM
WORKING signal are as follows:
Signal
|
Interpretation
|
I AM WORKING
output "On" continuously
|
Normal operation,
unit operating properly
|
I AM WORKING
output pulsed "On" and "Off"
|
Beyond set point,
unit operating properly
|
I AM WORKING
output "Off"
|
Loss of power
or unit inoperable
|
100% Set point and deadband adjustment
Set point and deadband values are adjustable over the full range span
using a convenient, simple to operate, front panel keypad. Access to the
programming mode requires a simple, yet tamperproof, keying sequence...
It's better than password protection!
Process variable extremes stored in non-volatile
memory
System pressure or temperature extremes are retained in the One Series'
non- volatile memory, assisting in troubleshooting problems. The One
Series captures high and low pressure or temperature extremes constantly.
Unique switch operating mode
The One Series provides four convenient switch operating modes which
determine the function of the switch output, deadband, LED status indicator
and I AM WORKING signal. The desired switch operating mode can
be selected from one of four options:
- High Limit Alarm - Close on Rise
- High Limit Shutdown - Open on Rise
- Low Limit Alarm - Close on Fall
- Low Limit Shutdown - Open on Fall
Excellent media compatibility
Pressure: Wetted materials include a 316 stainless steel pressure connection,
ceramic pressure sensor and your choice of O-ring material. The piezoresistive
ceramic sensor is compatible with most media except a few aggressive acids.
Temperature: 304 stainless steel sensor housing.
Back to top
Specifications
Patent
Pending
|
(Specifications
at 25°C and nominal voltage unless otherwise noted)
|
Enclosure
Specifications:
|
Die
cast aluminum epoxy powder coated; NEMA 4X (except "R"
temperature models. "R" models are weather tight but
do not carry a specific NEMA rating.)
|
Pressure
Ranges:
|
0 to 4000 psi.
See Model Charts
|
Wetted
Materials:
|
Process connection:
316 stainless steel
Sensor: Ceramic (96% Alumina)
O-Ring: Viton is standard. See
How To Order for other materials
|
Temperature
Ranges:
|
-50 to 1000°F
(-45.6 to 537.8°C) See Model Charts
|
Sensor
Housing:
|
304 stainless
steel
|
Extension
Wire:
|
Model H: MI extension
wire: 0.125" OD x 6, 10 or 20' long
Model R: Teflon® jacketed cable, Teflon® coated leads
with stainless steel over braid, 6', 10' or 20'
long
|
Weight:
|
Single enclosure
units: 1 3/4 lbs (0,8 kg)
dual enclosure units: 2 1/2 lbs (1,1 kg)
|
Shock:
|
MIL-STD-810E,
Method 516.4; 10 mSec @ 15 g's, 6 mSec @ 40 g's; 3 times
each axis
|
Vibration:
|
MIL-STD-810E,
Method 514.4; 10-2000 Hz @ 0.04 PSD (equates to 8 g's @ 2000
Hz)
|
Conduit
Connections:
|
Single
enclosure (switch rating A): 1/2" NPT female sealed conduit
connection
Dual enclosure (switch rating B and C):
1/2" NPT female conduit connection. Optional dual 1/2"
NPT female conduit connections
Dual enclosure (switch rating D): dual
1/2" NPT female conduit connections
|
Electrical
Connection:
|
Single enclosure
(switch rating A): 1 meter wire harness, 20 AWG, PVC jacketed,
shielded cable
Dual enclosure (switch rating B and C):
terminal block, accomodates 20 to 14 AWG conductors
Dual enclosure (switch rating D): separate
terminal blocks for high and low voltage signals, accomodates
22 to 14 AWG conductors
|
Power
Source:
|
24 VDC nominal;
18 to 30 VDC, 100 mA maximum (surge protected); optional 115 VAC
nominal, ± 10%
|
Switched
Output:
|
Switch rating
A & B: 100 mA @ 5 to 30 VDC, SPST MOSFET, open drain
(collector) sinking output, short circuit protected
Off state leakage current 10 µA @
30 VDC, fail safe "open"
Switch rating C: 15 Amp @ 24-280
VAC, SPST, solid-state relay; minimum load current is 150 mA
Off state leakage current 0.1 mA @
280 VAC, fail safe "open"
Switch rating D: 5 Amps @ 115 VAC.
SPST, solid state relay minimum load current is 150 mA.
Off state leakage current is 0.1 mA @
115 VAC, fail safe "open"
|
I
AM WORKING Output:
|
100 mA @
5 to 30 VDC, MOSFET, open drain (collector) sinking output, short
circuit protected
SPST off state leakage current 10 µA @ 30 VDC, fail
safe "open"
|
Optional
Analog Output:
|
4 to 20 mA sourcing
output, non-isolated, proportional to sensor input range, load
resistance 500W maximum
|
EMI/RFI:
|
Complies with
CE EMC requirements EN50081-1, EN50082-2 (switch rating B and
C only)
|
Emission:
|
Conducted emission
EN55011 class A; Radiated emission EN55011 class A
|
Immunity:
|
Electrostatic
discharge EN61000-4-2; Conducted disturbances (RF) acc. IEC 1000-4-6
Radiated E-fields (RF) acc IEC 1000-4-3,
acc ENV50204
Surge withstanding IEC 1000-4-5; Transient
withstanding EN 61000-4-4
|
Pressure
Ranges:
|
See
Model Charts
|
Temperature
Ranges:
|
See Model
Charts
|
Set
Point:
|
Adjustable over
the full range span. See Model Charts
|
Deadband:
|
Adjustable over
the full range span. See Model Charts
|
Maximum
Over Range:
|
See Model
Charts. N/A for temperature ranges
|
Burst
Pressure:
|
See Model
Charts. N/A for temperature ranges
|
Set
Point Repeatability:
|
±0.2% of
maximum range value
|
Accuracy:
|
Switch point/indication:
±1.0% of maximum range
Analog output: ±1.0% of maximum range
|
Media
Temperature Effects:
|
±1.0% of
maximum range from 32 to 158°F (0 to 70°C)
|
Long-Term
Stability:
|
±0.25% of
range per year, maximum
|
Switch
Response Time:
|
25 mSec typically,
200 mSec maximum
|
Ambient
Temperature:
|
Operating:
-22 to 158°F (-30 to 70°C)
Storage: -22 to 176°F (-30 to 80°C)
|
Media
Temperature For Temperature Models:
|
Limited by O-ring
material. See How to Order
|
Media
Temperature For Temperature Models:
|
-94 to 550°F
(-70 to 288°C)
-94 to 1150°F (-70 to 621°C)
|
Local
Digital Display:
|
2 Row by 16 character
LCD display for indication of programming parameters and process
variable; also displays extreme (min/max) pressure or temperature
values
|
Output
Status LED:
|
Local LED to indicate
switch and I AM WORKING output status
|
Field
Accessible Programming:
|
Convenient keypad
allows for easy product configuration and adjustment
|
Memory:
|
All programmed
data stored in non-volatile memory (saved when power lost)
|
I
AM WORKING States:
|
Signal
|
Interpretation
|
|
I AM WORKING output "On" continuously
I AM WORKING output
pulsed "On" and "Off"
I AM WORKING output
"Off"
|
Normal
operation, unit operating properly
Beyond set point, unit
operating properly
Loss of power or unit
inoperable
|
|
Approvals:
|
- UL Listed,
cUL Certified
- Class I, Division
2, Groups A, B, C, D
- Class II,
Division 2, Groups F, G
- Class III;
Enclosure type 4X (except "R" temperature models)
- Class I, Zone
2, Group IIC T4
- CE EMC Directive
(standard on switch rating B & C. N/A on switch relay
A and D)
|
Back to top
Model
Charts
Sensor Type 1, ½"
NPT Female, 316 stainless steel pressure connection, Viton O-ring, piezoresistive
ceramic pressure sensor
Model
|
Pressure
Range
|
Deadband
|
Maximum
Over Range
|
Burst
Pressure
|
| |
|
The
difference above or below set point at which the switch resets
to normal operation
|
The
value at which the sensor may experience irreversible damage
|
The
value at which the sensor may rupture
|
Low
|
High
|
psi/bar
|
psi
|
bar
|
psi
|
bar
|
psi
|
bar
|
A
|
0
|
25
|
1,7
|
Fully adjustable from 0% to 100% of range
|
50
|
3,4
|
100
|
6,8
|
B
|
0
|
50
|
3,4
|
100
|
6,8
|
200
|
13,6
|
C
|
0
|
125
|
9
|
250
|
18
|
500
|
36
|
D
|
0
|
250
|
17
|
500
|
34
|
1000
|
68
|
E
|
0
|
700
|
48
|
1400
|
96
|
2800
|
192
|
F
|
0
|
1400
|
96
|
2800
|
192
|
5600
|
384
|
G
|
0
|
2800
|
193
|
5600
|
386
|
11200
|
772
|
H
|
0
|
4000
|
276
|
8000
|
552
|
16000
|
1104
|
Sensor Type 2,
0.25" OD sensor housing, 304 stainless steel, 100 ohm RTD temperature
sensor
Model
|
Temperature
Range
|
Deadband
|
Maximum
Over Range
|
Description
|
| |
|
The
difference above or below set point at which the switch resets
to normal operation
|
The
value at which the sensor may experience irreversible damage
|
|
L1
|
-50
TO 450°F
-45 TO 232°C
|
Fully adjustable from 0% to 100% of range
|
550°F
288°C
|
Local
sensor, 4" long
|
L2
|
-50
TO 450°F
-45 TO 232°C
|
550°F
288°C
|
Local
sensor, 8" long
|
L3
|
-50
TO 450°F
-45 TO 232°C
|
550°F
288°C
|
Local
sensor, 10" long
|
R1
|
-50
TO 450°F
-45 TO 232°C
|
550°F
288°C
|
Remote
sensor, 6" long with 6' Teflon® extension
wire
|
R2
|
-50
TO 450°F
-45 TO 232°C
|
550°F
288°C
|
Remote
sensor, 6" long with 10' Teflon® extension
wire
|
R3
|
-50
TO 450°F
-45 TO 232°C
|
550°F
288°C
|
Remote
sensor, 6" long with 20' Teflon® extension
wire
|
H1
|
-50
TO 1000°F
-45 TO 538°C
|
1150°F
621°C
|
Remote
sensor, high temperature, 2.5" long with 6' MI extension
wire
|
H2
|
-50
TO 1000°F
-45 TO 538°C
|
1150°F
621°C
|
Remote
sensor, high temperature, 2.5" long with 10' MI extension
wire
|
H3
|
-50
TO 1000°F
-45 TO 538°C
|
1150°F
621°C
|
Remote
sensor, high temperature, 2.5" long with 20' MI extension
wire
|
Sensor Type 3,
1/4" NPT female pressure connections, silicon sensor with aluminum/plastic/glass/RTV
wetted parts. Suitable for sensing of dry air and inert gas.
Model
|
Differential
Pressure
Range
|
Deadband
|
Maximum
Differential
Pressure
|
Maximum
Working
Pressure
|
Differential
Burst
Pressure
|
K1
|
0
- 5" wcd
(12,4 mbar) |
Fully adjustable from 0% to 100% of range
|
1
psid
(0,1 bar) |
6
psig
(0,4 bar) |
5
psid
(0,3 bar) |
K2
|
0
- 25" wcd
(62,2 mbar) |
20
psid
(1,4 bar) |
100
psig
(6,9 bar) |
50
psid
(3,4 bar) |
K3
|
0
- 80" wcd
(199 mbar) |
20
psid
(1,4 bar) |
100
psig
(6,9 bar) |
50
psid
(3,4 bar) |
K4
|
0
- 5 psid
(344,7 mbar) |
30
psid
(2,1 bar) |
100
psig
(6,9 bar) |
80
psid
(5,5 bar) |
K5
|
0
- 12 psid
(827,4 mbar) |
60
psid
(4,1 bar) |
100
psig
(6,9 bar) |
120
psid
(8,3 bar) |
K6
|
0
- 35 psid
(2,41 bar) |
0
- 100 psid
(6,9 bar) |
100
psig
(6,9 bar) |
120
psid
(8,3 bar) |
Back to top
How
to Order
Build a part number by selecting appropriate
code for each feature category.
Example: D1A1B2NM446
D
|
1
|
A
|
1
|
B
|
2
|
N
|
M446
|
Setting/
Indication
Method
|
Series
Designation
|
Switch
Rating/
Termination
|
Sensor
Type
|
Model
|
*O-Ring
Material
|
Auxiliary
Output
|
Option(s)
|
*Not applicable for temperature
sensors
COMP0NENTS
CODE
|
DESCRIPTION
|
Setting/Indication
Method
|
D
|
User adjustable,
digital indicating configuration
|
Series
Designation
|
1
|
Designation for
One Series product line
|
Switch
Rating/Termination
|
A
|
Open drain (collector)
output with flying lead-wires
|
B
|
Open drain (collector)
output with terminal block (upper enclosure included)
|
C
|
15A solid-state
relay with terminal block (upper enclosure included)
|
D
|
5A solid-state
relay with 115 VAC internal power supply and terminal
|
Sensor
Type
|
1
|
Pressure, 316
stainless steel 1/2" NPT female, pressure connection, ceramic
sensor
|
2
|
Temperature sensor
|
3
|
Differential pressure
(dry air, inert gas)
|
Model
|
A,B,C,D,
|
See
Model Charts
|
E,F,G,H,
|
L1,L2,L3,
|
R1,R2,R3,
|
H1,H2,H3
|
K1,K2,K3
K4,K5,K6 |
O-Ring
Material (Not applicable for temperature sensors)
|
0
|
Viton; media temperature
0 to 257°F
(-17 to 125°C)
|
1
|
Aflas; media temperature
32 to 200°F
(0 to 93°C)
|
2
|
Buna N; media
temperature -22 to 257°F
(-30 to 125°C)
|
3
|
EPR; media temperature
-22 to 257°F
(-30 to 125°C)
|
4
|
Kalrez; media
temperature 32 to 257°F
(0 to 125°C)
|
Auxiliary
Output
|
N
|
None
|
A
|
4 to 20 mA analog
process signal
|
Option(s)
|
M025
|
5A, 200VDC(max.)
Relay Output
|
M026
|
Low Current and
Inductive Load Switching SSR
|
M027
|
VAC Power Supply
with Free SSR Contacts
|
M201
|
Factory set parameters
(set point, deadband and switch operating mode)
|
M205
|
Scale 4 to 20
mA Output
(Factory Configured, Customer Specified)
|
M270
|
Display and nameplate
units of measure in degree C (temperature units only)
|
M276
|
Display and nameplate
units of measure in bar (pressure units only)
|
M277
|
Display and nameplate
units of measure in kPa (pressure units only)
|
M278
|
Display and nameplate
units of measure in kg/cm2 (pressure units only)
|
M440
|
Cover chain
|
M444
|
Paper tag
|
M446
|
Stainless steel
tag
|
M550
|
Oxygen service
cleaning; may require Viton O-ring (pressure units only)
|
M905
|
1/2" NPT(F)
dual conduit entry
(switch rating C only)
|
L100
|
10 feet long cable
assembly (switch rating A only)
|
L200
|
20 feet long cable
assembly (switch rating A only)
|
|
Kit # 62169-19
3/16" Plastic barb fitting
(sensor 3 only)
|
Back to top |