EchoTouch™ Two Wire Ultrasonic Level Transmitter


  Process Controls Home
 
  Pumps
  Chemical Resistance
  Chlorine Systems
  Filtration
  Flow
  Hand Held Meters
  Level
  Mixers & Stirrers
  Monitors/Controllers
  Polyethylene Tanks
  Pulsation Dampeners
  Valves & Accessories
  Weighing Systems
  Weighing Systems
  Manufacturers
 
  Links
 
EchoTouch™ Two Wire Ultrasonic Level Transmitter
LU20-50_1
 
 
Application
Offered in CSA and Cenelec approved intrinsically safe or general purpose configurations, the two-wire ultrasonic transmitter provides non-contact level measurement up to 18 feet or 5.4 meters, and is ideally suited for challenging corrosive, slurry or waste liquids. The transmitter is typically selected for atmospheric bulk storage, day tank and waste sump applications located within a classified hazardous area. Media examples include diesel fuel and hydrochloric acid. See matrix to the right for more details.
Specifications
Range:
0.5' to 18' (15 cm to 5.4m)
Accuracy:
± 0.25% of span in air
Resolution:
0.125" (3 mm)
Beam width:
8° conical
Dead band:
0.5' (15 cm)
Display type:
LCD, 4-digit
Display units:
Inch or cm
Memory:
Non-volatile
Supply voltage:
12-32 VDC
Loop resist.:
600 Ohms @ 24 VDC
Signal output:
4-20 mA, two-wire
Signal invert:
4-20 or 20-4 mA
Calibration:
Digital, push button
Fail-safety:
Reverts to safe state during echo-loss
Process temp.:
F: -40° to 140°
C: -40° to 60°
Temp. comp.:
Automatic
Electronics temp.:
F: -4° to 140°
C: -20° to 60°
Pressure:
30 psi (2 bar) @ 25° C.,
derated @ 1.667 psi (0.113 bar)
per °C. above 25° C.
Enclosure rating:
NEMA 4X (IP65)
Installed height:
5.1" (13 cm) above tank process mount
Encl. material:
PP, UL94VO
Trans. material:
PVDF Kynar®
Process mount:
2" NPT (2" G)
Mount. gasket:
Viton® (G version only)
Conduit entrance:
Single, 1/2" NPT
Classification:
Intrinsically safe
Approvals:
CSA: Class I, Groups A, B, C & D;
Class II, Groups E, F and G;
Class III; T3C
EEx: Class 1, Division 1,
Groups A, B, C, D;
EEx ia IIC T3
Parameters:
CSA: Vmax < 32.0 V; Imax < 130 mA;
Ca = 0 µF; La = 0 µH
EEx: Ui = 32 V; Ii = 300 mA;
Pi = 1.3 W; Ci = 0 µF; Li = 0 µH
Certificates:
CSA: LR 79326
EEx: LCIE 01.E6060 X
CE compliance:
EN 50082-2 immunity
EN 55011 emission
Click here to download above specifications in a PDF file format.

Click here to download above Manual in a PDF file format.
 
Technology
ULTRASONIC
General purpose Yes
Conductive Yes
Non-conductive Yes
Conductivity Yes
Non-contact Yes
Clean Yes
Dirty Yes
Coating Yes
Non-coating Yes
Ambient pressure Yes
Low pressure Yes
Intrinsically safe Yes
Medium pressure No
Integral relay No
Foam No
Contact No
Vapors No
Gas density No
Vacuum No


Site Designed By Panther Marketing & Design