LI2_-1001 |
 |
|
|
|
|
|
|
Application |
| For simple wiring and indication, package the loop powered panel meter with any of our two-wire level transmitters. The general purpose meter is commonly used for local or remote indication of tank level in custom engineering units.
Offered in two enclosure types, the panel mount version is 1/8 DIN and features a NEMA 4X faceplate. The outdoor version is NEMA 4X with a rugged polycarbonate enclosure and clear faceplate. |
|
|
|
Specifications |
| Display type: |
LCD, 3.5-digit |
| Display units: |
Engineering |
| Display range: |
4 mA: ± 500
20 mA: 20-1999 |
| Display height: |
0.56" digits |
| Calibration: |
Potentiometer |
| Sensor input: |
(1) two-wire, 4-20 mA transmitter |
| Loop power: |
12-24 VDC @ 30 mA |
| Voltage drop: |
LI20: 1 VDC @ 20 mA
LI21: 1.5 VDC @ 20 mA
LI22: 3.5 VDC @ 20 mA |
| Electronics temp.: |
F: -40° to 149°
C: -40° to 65° |
| Enclosure type: |
1/8 DIN panel meter |
| Enclosure rating: |
LI20: NEMA 4X (faceplate)
LI21/2: NEMA 4X |
| Encl. material: |
Polycarbonate |
| Classification: |
General purpose |
|
|
Click here to download above specifications in a PDF file format. |
|
|
|
|
|
Technology |
| Not applicable for controllers and indicators. |
|
|