LZ10-14_ 5 |
 |
|
|
| Patent Pending |
|
|
|
Application |
| The tuning fork level switch is an excellent choice for more challenging application liquids including those with light to medium coating or scaling type characteristics. Liquid examples include light sodium hydroxide, brine and copper sulfate solutions.
The relay output provides a reliable switch interface with remote devices such as a PLC, SCADA or alarm. The general purpose sensor features a PP submersible probe and cable, and is designed for installation through the wall or inside the tank.
|
|
|
|
Specifications |
| Orientation: |
Universal |
| Accuracy: |
± 1 mm in water |
| Repeatability: |
± 0.5 mm in water |
| Supply voltage: |
12-36 VDC |
| Consumption: |
25 mA maximum |
| Contact type: |
(1) SPST relay |
| Contact rating: |
120 VAC/VDC @ 1A
(CE: 60 VAC/VDC @ 1A) |
| Contact output: |
Selectable NO/NC |
| Process temp.: |
F: -40° to 194°
C: -40° to 90° |
| Pressure: |
150 psi (10 bar) @ 25° C.,
derated @ 1.667 psi (0.113 bar)
per °C. above 25° C. |
| Sensor rating: |
NEMA 6X (IP68) |
| Sensor material: |
PP-Ryton® (glass fill) |
| Cable jacket mat.: |
PP |
| Cable type: |
4-conductor, #22 AWG (shielded) |
| Cable length: |
Standard: 10' (3m)
Special order: 25' (7.6m) or 50' (15.2m) |
| Process mount: |
3/4" NPT (3/4" G / Rp) |
| Mount. gasket: |
Viton® (G version only) |
| Classification: |
General purpose |
| CE compliance: |
EN 50082-2 immunity
EN 55011 emission
EN 61010-1 safety |
|
|
Click here to download above specifications in a PDF file format. |
|
|
|
|
|
Technology |
|
TUNING FORK |
|
General purpose |
Yes |
|
Foam |
Yes |
|
Bubbles |
Yes |
|
Conductive |
Yes |
|
Non-conductive |
Yes |
|
Clean |
Yes |
|
Dirty |
Yes |
|
Non-coating |
Yes |
|
Light coating |
Yes |
|
Medium coating |
|
|
Metallic tank |
Yes |
|
Non-metallic tank |
Yes |
|
PP sensor |
Yes |
|
Long sensor |
Yes |
|
Relay |
Option |
|
FET |
Option |
|
Intrinsically safe |
No |
|
PFA sensor |
No |
|
Short sensor |
No |
|
Reed |
No |
|
Heavy coating |
No |
|
|
|