Switch-Tek,Non-intrusive,RF Capacitance Level Switch,Flowline

Switch-Tek™ Non-intrusive RF Capacitance Level Switch
From Flowline


  Process Controls Home
 
  Pumps
  Chemical Resistance
  Chlorine Systems
  Filtration
  Flow
  Hand Held Meters
  Level
  Mixers & Stirrers
  Monitors/Controllers
  Polyethylene Tanks
  Pulsation Dampeners
  Valves & Accessories
  Weighing Systems
  Weighing Systems
  Manufacturers
 
  Links
 
Switch-Tek™ Non-intrusive RF Capacitance Level Switch
LP50-_005
 
Patent Pending
 
Application
The non-intrusive capacitance level switch mounts on the exterior wall of non-metallic tanks and is an excellent choice for clean, conductive, non-coating or scaling type liquids. Media examples include deionized water, nitric and hydrofluoric acids. The relay output provides a reliable switch interface with remote devices such as a PLC, SCADA or alarm. Offered in general purpose and intrinsically safe versions, the non-intrusive sensor detects liquid through the wall of any plastic or fiberglass tank.
Specifications
Tank mounting: Non-intrusive
Tank mat. comp.: Non-metallic
Tank wall thick.: < 1" (25 mm)
Accuracy: ± 1 mm in water
Repeatability: ± 0.5 mm in water
Dielectric range: > 10 constants
Conductive range: > 100 micromhos
Supply voltage: 12-36 VDC
Consumption: 25 mA maximum
Contact type: (1) SPST relay
Contact rating: 120 VAC/VDC @ 1A
(CE: 60 VAC/VDC @ 1A)
Contact output: Selectable NO/NC
Process temp.: F: -40° to 194°
C: -40° to 90°
Enclosure rating: NEMA 4X (IP65)
Enclosure mat.: PSO
Conduit entrance: Single, 1/2" NPT
Bracket material: 1005: PP
5005: PVDF
6005: PE
7005: PVC
Bracket mounting: 3M adhesive / plastic thermal weld
Cable jacket mat.: PP
Cable type: 4-conductor, #22 AWG (shielded)
Cable length: Standard: 10' (3m)
Special order: 25' (7.6m) or 50' (15.2m)
Classification: General purpose
CE compliance: EN 50082-2 immunity
EN 55011 emission
EN 61010-1 safety
Click here to download above specifications in a PDF file format.
 
Technology
CAPACITANCE
General purpose Yes
Bubbles Yes
Conductive Yes
Clean Yes
Non-coating Yes
Non-metallic tank Yes
PS sensor Yes
Relay Option
FET Option
Intrinsically safe Option
Non-conductive No
Dirty No
Foam No
PFA sensor No
Metallic tank No
Reed No
Light coating No
Medium coating No
Heavy coating No