| Range: |
0.16' to 4'
(5 cm to 1.2m) |
| Resolution: |
0.125" (3 mm) |
| Repeatability: |
0.25" (6 mm) |
| Hysterysis: |
0.4" to 3.9" (1 to 10 cm) |
| Beam width: |
2" diameter |
| Dead band: |
0.16' (5 cm) |
| LED indication: |
Power, calibration and
echo status |
| Calibration: |
MicroCal software with
IR-cable interface |
| Memory: |
Non-volatile |
| Supply voltage: |
50_5: 120 VAC
52_5: 240 VAC
58_5: 12-28 VDC |
| Consumption: |
AC: 5 watts max.
DC: 65 mA @ 24 VDC |
| Contact type: |
50_5: triac
52_5: triac
58_5: FET |
| Contact rating: |
50_5: 120 VAC @ 1A
52_5: 250 VAC @ 1A
58_5: 30 VDC @ 100 mA |
| Contact output: |
Specified NO/NC |
| Contact logic: |
Single point: alarm
Two point: latching |
| Contact fail-safety: |
Reverts to de-energized
state during echo-loss |
| Process temp.: |
F: -40° to 160°
C: -40° to 71° |
| Temp. comp.: |
Automatic |
| Electronics temp.: |
F: -40° to 160°
C: -40° to 71° |
| Pressure: |
30 psi (2 bar) @ 25° C., derated @
1.667 psi (.113 bar) per °C. above 25° C. |
| Enclosure rating: |
NEMA 6X (IP67) |
| Installed height: |
1.7" (4.3 cm) above
tank process mount |
| Encl. material: |
PC/ABS FR |
| Trans. material: |
PVDF Kynar® |
| Cable material: |
Polypropylene |
| Cable type: |
6-conductor |
| Cable length: |
10' (3m) |
| Process mount: |
1" NPT (1" G) |
| Mount. gasket: |
Viton® (G version only) |
| Classification: |
General purpose |
| CE compliance: |
EN 50082-2 immunity
EN 55011 emission
EN 61010-1 safety |