A_13-_2_ _ |
 |
|
|
|
|
|
|
Application |
| This general purpose switch packageprovides a complete solution for high level spill prevention or low level pump protection with a fixed level switch point and 10A compact relay controller for pump or valve actuation.
The optional flash alarm brings immediate attention to high level conditions. The product is typically selected for pressurized and/or highly corrosive bulk storage, day tank and waste sump applications. Specify the appropriate sensor technology, material and assembled dimension. |
|
|
|
Specifications |
| Length: |
6" to 10' (15 cm to 3m) |
| Switch point: |
1 (set by factory) |
| Orientation: |
± 30° vertical |
| Supply voltage: |
120/240 VAC @ 50-60 Hz. |
| Contact type: |
(1) SPDT relay |
| Contact rating: |
250 VAC @ 10A |
| Contact delay: |
0-60 seconds |
| LED indication: |
Power, relay and sensor status |
| Strobe type: |
_21_: Xenon tube
_22_: N/A |
| Strobe flash: |
_21_: 1 per second
_22_: N/A |
| Process temp.: |
F: -40° to 194°
C: -40° to 90° |
| Electronics temp.: |
F: -40° to 140°
C: -40° to 60° |
| Pressure: |
AU13: 150 psi (10 bar)
AZ13: 150 psi (10 bar)
AV13: 25 psi (1.7 bar) |
| Wetted material: |
42__: PP
52__: PVDF Kynar® |
| Process mount: |
_2_3: 2" NPT
_2_7: 1 1/2" G |
| Enclosure rating: |
NEMA 4X (IP65) |
| Installed height: |
_21_: 6.5" (16.5 cm)
_22_: 4.9" (12.4 cm) |
| Encl. material: |
_21_: PP, UL94VO and polycarbonate
_22_: PP, UL94VO |
| Conduit entrance: |
Single, 1/2" NPT |
| Classification: |
General purpose |
| CE compliance: |
EN 50082-2 immunity
EN 55011 emission
EN 61010-1 safety |
|
|
|
|
|
|
Technology |
|
TUNING FORK |
|
General purpose |
Yes |
|
Foam |
Yes |
|
Bubbles |
Yes |
|
Conductive |
Yes |
|
Non-conductive |
Yes |
|
Clean |
Yes |
|
Dirty |
Yes |
|
Turbulent |
Yes |
|
Non-coating |
Yes |
|
Light coating |
Yes |
|
Medium coating |
Yes |
|
Relay |
Yes |
|
PP sensor |
Yes |
|
PVDF sensor |
No |
|
Intrinsically safe |
No |
|
Heavy coating |
No |
|
CAPACITANCE |
|
General purpose |
Yes |
|
Foam |
Yes |
|
Bubbles |
Yes |
|
Conductive |
Yes |
|
Non-conductive |
Yes |
|
Clean |
Yes |
|
Dirty |
Yes |
|
Turbulent |
Yes |
|
Non-coating |
Yes |
|
Light coating |
Yes |
|
Medium coating |
Yes |
|
Relay |
Yes |
|
PP sensor |
Yes |
|
PVDF sensor |
No |
|
Intrinsically safe |
No |
|
Heavy coating |
No |
|
ULTRASONIC |
|
General purpose |
Yes |
|
Foam |
Yes |
|
Conductive |
Yes |
|
Non-conductive |
Yes |
|
Clean |
Yes |
|
Dirty |
Yes |
|
Turbulent |
Yes |
|
Non-coating |
Yes |
|
Light coating |
Yes |
|
Relay |
Yes |
|
PP sensor |
Option |
|
PVDF sensor |
Option |
|
Intrinsically safe |
No |
|
Bubbles |
No |
|
Medium coating |
No |
|
Heavy coating |
No |
|
BUOYANCY |
|
General purpose |
Yes |
|
Foam |
Yes |
|
Bubbles |
Yes |
|
Conductive |
Yes |
|
Non-conductive |
Yes |
|
Clean |
Yes |
|
Turbulent |
Yes |
|
Non-coating |
Yes |
|
Relay |
Yes |
|
PP sensor |
Yes |
|
PVDF sensor |
Option |
|
Intrinsically safe |
No |
|
Dirty |
No |
|
Light coating |
No |
|
Medium coating |
No |
|
Heavy coating |