Symprobe,Self Grounding,RF Capacitance Level Transmitter,Flowline

Symprobe Self Grounding RF Capacitance Level Transmitter
From Flowline


  Process Controls Home
 
  Pumps
  Chemical Resistance
  Chlorine Systems
  Filtration
  Flow
  Hand Held Meters
  Level
  Mixers & Stirrers
  Monitors/Controllers
  Polyethylene Tanks
  Pulsation Dampeners
  Valves & Accessories
  Weighing Systems
  Weighing Systems
  Manufacturers
 
  Links
 
Symprobe Self Grounding RF Capacitance Level Transmitter From Flowline
LP75-20_1-_
 
 
Patent Pending
 
Application
The two-wire, self grounding capacitance level transmitter is mounted through the top wall of the tank and provides continuous measurement up to 10 feet. This device is ideal for use with general purpose intermediate storage tanks and process vessels. The transmitter is best applied in conductive, non-coating or scaling type liquids including clean water, acid and chemical solutions. The all FEP Teflon probe is an excellent choice for highly corrosive media such as hydrochloric acid.
Specifications
Range:
1' to 10' (30 cm to 3m)
Accuracy:
± 1% of full span
Resolution:
0.125" (3 mm)
Conductive range:
> 100 micromhos
Dielectric range:
> 20 constants
Capac. range:
100 to 1000 pF
LED indication:
Power status
Supply voltage:
14-36 VDC
Loop resist.:
600 Ohms @ 24 VDC
Signal output:
4-20 mA, two-wire
Signal invert:
4-20 or 20-4 mA
Calibration:
Potentiometer
Process temp.:
F: -40° to 158°
C: -40° to 70°
Electronics temp.:
F: -40° to 140°
C: -40° to 60°
Pressure:
75 psi (5 bar) @ 25° C.,
derated @ 1.667 psi (0.113 bar)
per °C. above 25° C.
Enclosure rating:
NEMA 4X (IP65)
Installed height:
4.8" (12.2 cm) above tank process mount
Encl. material:
PP, UL94VO
Probe material:
FEP Teflon®
Process mount:
3/4" NPT (3/4" G)
Mount. gasket:
Viton® (G version only)
Conduit entrance:
Single, 1/2" NPT
Classification:
General purpose
CE compliance:
EN 50082-2 immunity
EN 55011 emission
Click here to download above specifications in a PDF file format.
 
Technology
CAPACITANCE
General purpose Yes
Conductive Yes
Clean Yes
Foam Yes
Non-coating Yes
Contact Yes
Vapors Yes
Gas density Yes
Vacuum Yes
Ambient pressure Yes
Low pressure Yes
Medium pressure Yes
Intrinsically safe No
Non-conductive No
Conductivity No
Non-contact No
Dirty No
Coating No
Integral relay No