Blank
Melt Bolts
These are used to close
or block existing melt temperature or pressure vents, where pressure
transducers or temperature thermocouples are no longer being used.
Available in 316 stainless in various lengths these blank bolts are
rated for pressures in excess of 15,000 PSI.
Rupture Disc
Pressure
sensitive discs are used as over pressure protectors, when normal
running pressures are exceeded. These are made of stailess steel and
fit most extruders that have melt pressure or melt thermocouple vents
on the barrel. Rupture discs are a safety device that release pressure,
should they exceed the pressure that they are manufactured to collapse
at. Typical burst pressures are 4000, 4500, 5000, 6500, 7500, and
9500. Normal stem lengths are, 3" and 6" with 1/2- 20 UNF
threads and a hex bolt for installation and removal.
Melt Temperature
Thermocouple
These
are temperaure sensors that are used in extruders where plastic melt
temperatures need to be measured. They are ruggedly manufactured in
316 Stainless steel with fglexible armour construction along with
a high temperature plug. Various tip and body sizes ensure direct
replacement of pre-existing temperature probes. Standard sizes are
6" stem length with 12" of flex armour. Longer lengths of
bolt sizes and leads are also available. Noemal thread size is a 1/2-20
UNF in a type J or K Thermocouple calibration.
Melt Pressure Indicator
Controller
Are highly
accurate devices, that ensure a very high degree of stability and
repeatability when measuring Extruder Melt Pressure. These units are
available in a variety of ranges from 0 to 20,000 PSI and have overload
pressure capabilities of twice the rated pressure range. They are
high temperature devices that withstand 750ºF (400ºC) and
are available with built in thermocouples, or with 18" of flex
armour cables. Melt pressure transducers are also available in EXPLOSION
PROOF construction to meet CLASS I, DIVISION I, Group B, C, and D.
Made of Stainless Steel they have an industrial standard 1/2 - 20
UNF thread alongwith a hex nut that facilitates installation and removal.
Pressure transducers work on strain guage principles and have the
following.
Specifications
Accuracy. . . . . . . . . . . . . . . . . +/- 0.5 % or 1 % of full scale
Repeatability. . . . . . . . . . . . . . .+/- 0.1 % of full scale
Sensitivity. . . . . . . . . . . . . . . .3.33 millivolt/volt
Excitation. . . . . . . . . . . . . . . . 6 to 10 volts DC
Diaphragm Material. . . . . . . . . . . . 5-5PH Stainless Other materials available