Limit Controllers

Features:

• FM approved limit controller
•
Comnact economical 1 / 16 DIN size

•
Easy to use yet powerful

•
Time of over temperature condition indication
• User selectable as a high or low limit
• Universal Inputs, Timer, Register, Retransmission, Communication
•
NEMA 4 IP65 Front Panel


This FM approved Limit Controllers will shut down the process by disconnecting power from the process if the controller reads a value above setvalue for a Hi Limit Controller or below set point if configured as a low limit control. The controller will remain in this state until the temperature has dropped below the set value and the reset button has been pressed. The control also has a timer to indicate the total time the setpoint is exceeded i e (duration of over temperature) it also has a register that will indicate the maximum temperature reached. Field programmable Low / High Process alarms and deviation alarms or band alarms are an option.

Specifications:

INPUT
Programable. . . . . . Thermocouple, J K T R B S L N
                       RTD, PT 100
                       mV, 0-50mV DC
                       VDC, 0-5VDC 1-5VDC, 0-lOVDC, 2-lOVDC
                       mA, 0-20mA 4-20mA
    Remote Reset Input Voltage free contact closure required for reset
    Input sampling rate 0.25s
OUTPUTS
Output 1. . . . . . . .Limit Relay SPDT 5Amp at 120/240 VAC resistive
Output 2. . . . . . . .Alarm/Annunciator SPDT 2A  120/240 VAC resistive
Output 3. . . . . . . .DC Linear ( recorder ) 0-20mA 4-20mA 0-l OV 0-5V
                       SPDT relay 2A resistive 120/240 VAC
OUTPUT. . . . . . . . .Limit Control Output
Output type selection
The output type (high limit type or Low limit type) is selectable by the user via dipswitch.
Accuracy. . . . . . . .+ -0.3%(of output span)
Noise-rejection ratio. Normal Mode 40dB (50/60Hz)
                       Common mode 120dB(50/60Hz)
Retransmission output (Optional specifications RET)
ALARMS. . . . . . . . .Two soft alarms upto two outputs can be used for alarms
Combination Alarms. . .Logical OR or AND of alarms to an individual hardware output
COMMUNICATION
Baud rate. . . . . . . 1200,2400,4800,9600 BPS
Type. . . . . . . . . .Serial asynchronous UART to-UART link RS 485
Max # of zone. . . . . 32
Physical Layer. . . . .RS 485
Operating Temp. . . . .0 to 55 deg C
RH. . . . . . . . . . .20% - 95% nn condensing
Supply Voltage. . . . .90 - 264 VAC 50/60 Hz or 22-50 VDC ( Optional )
Accuracy. . . . . . . .+/- .25% of span +/- LSD
Dimensions. . . . . . .48 X 48 X 100 mm

 

Heating & Control Systems Product Line
 
 

13-60 MEG DR
LONDON, ON Canada N6E 3T6
Tel: (519) 686-6095
Fax : (519) 686-8159

Home | Need A Quote | Online Magazine | Online Buyers Guide | Company Directory | Product Sites

Limit Controllers

Copyright Owner:
Process Controls and Instrumentation
102 Wellington St E
Alliston ON L9R 1G7
Tel: (705) 435-9112 Fax: (705) 435-5277
email: webmaster@process-controls.com