Standard inputs thermocouple, RTD
• Heat/Cool action
• Relay, Triac, DC voltage pulse or current output
• Heater break alarm for monitoring multiple parallel
heaters
• Loop break alarm for heater breaks/shorted sensors
or relays
This PID Temperature Controller
features dual displays & selectable inputs. These controls
are easy to operate and the out can be ordered for a relay contact,
a voltage pulse, or a 4 to 20 mAmp output This controller also
excepts various inputs from f thermocouples, RTD, DC voltage
and DC current. In addition these controllers can have 2 independent
alarm contacts that are programmable to be deviation, process,
or set value alarms. The Heater break alarms utilize an external
current transformer that monitors the heater current and activates
an alarm should the current fall below a threshold value that
has been set by the operator. The loop break monitors and protects
the entire temperature control system. The loop break alarm
will detect Heater Breaks, Thermocouple or RTD failure, short
circuits, or the failure of an operating device such as a mechanical
relay, Mercury Relay or SSR.
Specifications
Input
Thermocouple. . . . . . . . .K,J,R,S,B,T,L,N,E,PLII W5Re/W26Re.
RTD. . . . . . . . . . . . . (PIIOO,JPll OO) -199.9-649.0C -199.9-999 OF
DC voltage. . . . . . . . . .(0-5V,1-5V) 0.0-100%(fixed)
DC current. . . . . . . . . .(0-20mA, 4-20mA) 0.0-100%(fixed)
Control Output
Relay. . . . . . . . . . . . 25OVAC, 3A Form A or Form C contact
Voltage pulse. . . . . . . . 0/l2VDC, load resistance more than 600 Ohms
Current. . . . . . . . . . . 4-20mA DC load resistance less tham 600 Ohms
HBA Alarm
Input. . . . . . . . . . . . Output signal from CT
Range. . . . . . . . . . . . 0-30A or 0-100A
Accuracy. . . . . . . . . . .+/-0.5% or 2A whichever is larger
Relay output. . . . . . . . .25OVAC,1 A contact
Heating load draw:. . . . . .30 or 100 amps must be specified
LBA Alarm
Setting range 0.1-200.0 minutes.
Relay output 25OVAC,1 A contact
Control Action
a) PID action with autotuning
b) Heat/cool PID action with autotuning (not available on REX-C100)
Heating proportional band(P). 1-100% of input range.
Cooling proportional band. . .1-1000% of heating proportional band
Integral(1). . . . . . . . . .1-3600 seconds
Derivative(D). . . . . . . . .1-3600 seconds
ARW. . . . . . . . . . . . . .1-100% of proportional band
Heating cycle. . . . . . . . .1-100 seconds
Cooling cycle. . . . . . . . .1-100 seconds
Sampling Rate 0.5 seconds
Setting Accuracy Thermocouple input.+/-(0.5% of SV + 1 digit)
RTD input. . . . . . . . . . . +/-(0.5% of SV + 1 digit) 0.8C(1.6F)
External Dimensions
REX-C100. . . . . . . . . . . .48 x 48 x 100mm
REX-C400. . . . . . . . . . . .96 x 48 x 100mm
REX-C410. . . . . . . . . . . .48 x 96 x 100mm
REX-C700. . . . . . . . . . . .96 x 96 x 100mm
Supply Voltage 90-264VAC (50/6OHZ)