Accutherm offers high quality circulation heaters, suitable for heating liquids and gases. A wide selection of tubular elements in stock provide quick delivery of our catalog heaters.
Application Circulation heaters heat flowing liquids and gases. Accutherm offers a wide selection of vessel material, housings, sensors and temperature controls. Accutherm has HOT IDEAS for all your tubular element needs.
Standard Features
- UL & CSA recognition on elements.
- 334 stainless steel sheath (equivalent to Incoloy 840) standard for most applications and temperatures.
- Type 'A' 80/20 resistance wire sized to provide low wire watt density for maximum life.
- Fusion welded junction between pin and resistance wire for superior strength.
- High purity MgO compacted to provide maximum heat conductivity and optimum dielectric integrity.
- Recompacted bends on hairpin end of elements to restore MgO density.
- Terminal ends moisture sealed against the entrance of contaminants during storage and service.
- #10-32 terminals with screw lug line connectors.
- Welded construction between elements and screwplugs or flanges; silver braze construction on non ferrous materials.
- ALL joints between elements and screwplug or flange pressure tested for leaks.
- Spacer supports on units where immersed length exceeds 18".
- NEMA 1 housings; seamless and deep drawn on all screwplug heaters and flange heaters 8" and under, to provide accessibility to wiring, plus afford a degree of protection against splashing or dripping liquids.
- 1/2" O.D. thermowell for existing or optional thermostat.
- 100% inspected for:
- Dielectric or Hi-Pot between conductors and sheath of element.
- Insulation resistance.
- Wattage
Optional Features
- ASME Section VIII , Div. 1, design and code stamp available.
- NEMA 4 moisture or NEMA 7 explosion resistant enclosures available on all screwplug and flange sizes.
- Standoff housing design for high temperature applications.
- Thermostat controls available in three temperature ranges, inside NEMA 1, 4, or 7 housings.
- MgO filled type J or K thermocouples for control or high limit protection.
NOTE: Hi-limit thermocouples welded to element sheath provides positive sensing protection for over heat situations. Thermocouple junction should be at area of highest operating temperature.
- Various selection of sheath materials... Monel 400, Inconel 600, Hastelloy, Carpenter 20, and Titanium.
- Vessels, flanges and screwplugs are also available in a wide variety of materials, some of these include Steel, 304 Stainless Steel, and 316 Stainless Steel.
- Passivation or Electropolishing on elements, plugs, flanges and vessels for pure and deionized water, photo chemicals and special processes.
- Baffle assembly between elements to direct flow through the vessel.
- Special lengths, wattage's and voltages... consult factory.