TH3PL Timers

The TH3PL timers are solid-state output single shot timers in a fully encapsulated 2" x 2" case. Time adjust can be with onboard potentiometer, external resistor or factory fixed time.

  Download

Timing Mode

Power must be applied to the input voltage terminals continuously. Upon closure of a Normally Open (N.O.) external initiate switch, the load is instantly energized and the time delay cycle starts.

Maintained closure or actuation of the external initiate switch during the delay cycle will not affect the time delay period.

When the delay period expires, the timer will reset to its original position and the timer is ready for another cycle.

FEATURES
  • Digital timing, solid-state output
  • 1 Amp current handling
  • 10 Amps single AC cycle surge handling
  • ±0.1% Repeat accuracy
  • Factory-fixed or variable-timing adjust
  • Single screw mounting through center mounting hole
  • Standard 6.35mm (.250) quick connect blade terminals
  • 100% Operational testing before shipping
BASIC WIRING AND DIMENSIONS
SPECIFICATIONS

Input Voltage:

  • VAC: 24, 120
  • VAC: 230 (±20%)

Initiate: Switched line voltage

Time Delay:

  • 0.1 sec. to 24 hours
  • (1 sec. 10 sec. 100 sec., and 1000 sec. are standard)
  • Any time range available upon request

Repeatability: ±0.1% under fixed conditions

Reset/Recycle Time: 150 milliseconds maximum

Initiate Time: 16 milliseconds

Solid-State Output Form:

  • Normally open 1 Amp steady state
    - 10A single cycle surge

Life Expectancy:

  • No predictable failure if used within operating parameters

Protection:

  • Transient Protection: 18 joules
  • Dielectric Strength: 1800 RMS 60 Hz

Temperature Ranges:

  • Storage: -40°C to +85°C
  • Operating: -40°C to +75°C

Physical Data:

  • Surface mount with single #8 or #10 screw
  • Totally encapsulated
SELECTION PROCEDURE
Mode of Operation Series Input Voltage Time Ranges Time Adjustment
Method
Single Shot TH3PL
  1. 120 VAC
    50/60 Hz
  2. 230 VAC
    50/50 Hz
  3. 24 VAC
    50/60 Hz
VARIABLE TIME PERIODS
  1. Variable, integral,
    knob on timer
  2. Variable, external potentiometer supplied
  3. Fixed, integral, factory set
  4. External, remote resistor
0001 .1 to 1 sec.
0010 .1 to 10 sec.
0100 1 to 100 sec.
1000 10 to 1000 sec.
Any range up to 24 hours
avaialble