Rotronic,FH,Series,Specifications

Rotronic FH Series
Specifications


  Rotronic FH Series Combines Advance Probe Technology With A Robust Design
  FH Series Specifications

Datasheet | Specifications | Diagrams | Installation | Accessories | Probe Calibration


Technical data
Configurations F22H-65: wall mount or remote probe, 2-wire, loop powered
F22H-31: duct mount, 2-wire, loop powered
FH-65: wall mount or remote probe, 3-wire
FH-31: duct mount, 3-wire
Probe HygroClip S plug-in probe (included with transmitter)
Humidity sensor ROTRONIC Hygromer® C94 (capacitive)
Temperature sensor RTD Pt100 Ohm, 1/3 DIN
Sensor protection Wire mesh filter (standard) / foam filter (optional)
Probe operating/measuring range 0...100%RH
-40...85°C / -40...185°F
Transmitter operating limits 0...100%RH and -5...60°C (23...140°F)
Standard measuring ranges 0...100%RH
0...100°F, 0...200°F, 0...50°C, -30...70°C - other ranges on request
Accuracy at 23°C / 73°F <±1.5%RH and ±0.3°C / 0.5°F - special calibration on request
Repeatability better than 0.5%RH and 0.1°C/°F
Output signals 4...20mA, 0...5V (3-wire only)
Supply voltage 2-wire, loop powered: 8VDC + 0.02 x load, 35VDC max.
3-wire: 24VAC or 10 ...35VDC (15VDC min. for 4-20mA)
Materials Enclosure: ABS, HygroClip S: Polycarbonate
Case protection grade  IP65 / NEMA 4
Weight 300 g / 0.7 lb