Temperature
Measuring Instruments
SmartReader
1 is an easy to use data logger for effortless temperature
recording. Quick and easy to set up, it works right
out of the box, logging temperature readings from its
internal, precision-calibrated, on-board sensor. For
added versatility, you can also use an optional remote
temperature probe.
|
SmartReader
1
|
|
Memory Size: |
32 KB. |
|
Accessories: |
ACR
ET Series Temperature Probe. |
|
No. of Channels: |
Two. (One for the internal temperature sensor and
one for remote sensing of temperature, resistance,
or switch status). |
|
PDF: |
View
PDF |
|
Multi-channel,
Configurable, 8-Bit Data Loggers
|
|
Size: |
107 X 74 X 22 mm (4.2 X 2.9 X 0.9").
|
|
Weight: |
110 grams (3.75 ounces) |
|
Case Material: |
Noryl® Plastic |
|
Operating Limits: |
-40°C to 70°C (-40°F to 158°F)
and 0 to 95% Relative Humidity (non-condensing).
|
|
Clock Accuracy: |
+/-2 seconds per day. |
|
Battery: |
3.6 volt Lithium, 1 Amp-Hour |
|
Power Consumption: |
5 to 10 microamps (continuous). |
|
Battery Life: |
10-years warrantied (under normal use.) Factory
replaceable. |
|
Mounting: |
Magnetic backing or locking eyelet.
|
|
Memory Size: |
32 K (32,768 readings). |
|
Sampling Method: |
1. Continuous (First-in, First-out) 2. Stop
when full
(Fill-then-stop). |
|
Sampling Rate: |
User selectable rates between 8 seconds to
once every 5 days. |
|
Resolution: |
8 bits (1 part in 256). |
|
External Connector: |
Removable screw-type terminal strip with Common
(-) connection. |
| PDF
|
Click
Here |
|
PC Requirements: |
IBM PC or 100% compatible running MS® Windows
3.1, '95, '98, or NT, with at least 2 MB RAM,
2 MB of hard drive disk space and one free serial
port. |
Product Approvals: |
Meets Part 15 for Digital Devices of the Code
of Federal Regulations of the Federal Communications
Commision (FCC). Meets Class A radiated and
conducted emission requirements of Section 2
of the Radio Interference Regulations of Communications
Canada. IEC801-2, 3, 4 and EN55011 covering
ESD, RFI Immunity, EFT/Burst and Radiated Emissions
respectively, for the Commission of the European
Communities (CE). |
Resistance to X-Rays: |
Tested for protection against a 160kV dose @
5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D.
(about 100 times that of an airport X-Ray machine).
Tested for protection against Gamma Ray (equivalent
to 0.137 - 1.38 mega volts) IR 192 - 28 curies
@ 30 second exposure source to object distance
5". |
Internal
Temperature Sensor |
Type:
|
Negative Temperature Coefficient Thermistor.
10,000 ohms @ 25°C (77°F).
|
Tolerance (sensor only): |
+/-0.2°C, over the range of 0 to 70°C
(+/-0.3°F, over the range of 32 to 158°F).
|
Range: |
-40° to 70°C (-40° to 158°F).
|
Resolution: |
0.4°C (0.7°F) @ 25°C. Better
than 1°C (1.8°F) between -25°C
(-13°F) and 70°C (158°F). Better
than 2.0°C (3.6°F) between -40°C
(-40°F) and 25°C (-13°F)
|
|
PC
to SmartReader Communications
To
setup, download or view realtime information from
an ACR SmartReader Data Logger, all that is required
is an ACR IC-101 Interface Cable. Connection is
simple. Plug the IC-101 connector into your PC's
serial port and the stereo cable into the ACR Data
Logger. The IC-101 cable is included with the ACR
TrendReader Interface Package. No tools, interface
cards or docking stations required. You can setup,
download or view realtime information from up to
8 loggers at once, locally or over a modem.
|
 |
TrendReader®
Software
TrendReader®
for Windows® is a powerful, versatile, and
easy to use software package designed exclusively
for ACR's SmartReader, SmartReader Plus and OWL
Data Loggers. Powerful features and easy setup enables
logged data to be collected and thoroughly analyzed
in seconds. |
|
Fast
and Easy Logger Setup
Since
TrendReader® comes complete with built-in menus
for Sample Rate, Start Delay, Equations and more,
setup is fast and easy. In addition, equations are
already included for all ACR accessories so users
need only select the appropriate equation from the
menu. Realtime readings are displayed in the Setup
window, allowing you to ensure that your logger's
setup is correct before placing it in the field. |
 |
One-Touch
Table View
With
ACR's TrendReader® Software, logged data can
be viewed in Table format to permit detailed analysis
of logged data. Multiple channels of data can be
displayed at once with each reading displaying the
time and date. You can even select portions of,
or all the table information and paste it into your
favorite Windows® presentation or word processing
program.
|
 |
Presentation
Quality Graphs
TrendReader®
allows you to present logged data the way you want.
Multiple logged data sets can be displayed and compounded
to create new graphs. For added presentation power,
TrendReader® lets you add comments, change
graph colors, zoom in on specific portions of data,
display your data using custom engineering units
and print to any Windows® compatible printer
with ease. TrendReader® even lets you copy/paste
your graphs directly into your case reports. If
you prefer to use Excel,® Lotus® or other
popular spreadsheet programs, data can be exported
into ASCII and CSV formats.
|
 |
|