Variable,Area,Flow,Meters,Lake,Monitors

Variable Area Flow Meters
From Lake Monitors


  Home | About Us | Contact | New Products

Pumps
 ARO Pumps
 Caster Pumps
 Flux Pumps
 Gidding & Lewis
 Grundfos

 Pulsafeeder

 Promag
 Viking Pump
  
Flow Meters
 Burkert Contromatic
 Hays
 Kobold
 
Lake Monitors

  
Mixers
 Midwest Mixing
 TAH Industries
 
Pulsation Dampeners
 ARO Pumps
  
Pressure
 Winters Thermoguages
 
Strainers
 Hayward Industrial
 
Valves
 Burkert Contromatic
 Dynalfluid 2000
 
Web Site & Email
 Web Site
 Email Us
 
Web Site Tools
 



 
  Variable Area Flow Meters

Download PDF File: Data Sheet No. B-699

• Three Materials of Construction: Select from aluminum, brass or stainless steel.
• Flexible Mounting Requirements: Allows the designer to mount the monitor in any orientation; horizontal, vertical or inverted.
• Superior Exterior Design: Weather-tight for use outdoors and/or on systems where washdowns are required.
• Reverse Flow Capability: An option not found in most rotameters and other variable area meters.
• Good Viscosity Stability: A thin (0.03"), sharp-edged, orifice provides excellent stability of readings to a minimum of 500 SUS.
• Rugged and Reliable: Designed as a hydraulic service tool, this monitor will provide years of maintenance free performance.
• High Pressure Operation: The magnetically coupled follower allows operation to 6000 PSIG and use with opaque liquids.
• Twenty-three Different Ports Available: Standard selection of NPT, SAE and BSP permits system design versatility.
• Reverse Flow Capability: An option not found in most rotameters and other variable area meters.
ENGINEERING SPECIFICATIONS:

The in-line flow rate monitor shall:
• use the variable annular orifice technique with compression spring recovery.
• not require inlet or outlet straight plumbing, or require vertical pipe mounting.
• have a measuring accuracy of ±2.5% of full scale in the center third of the measuring range, and ±4% of full scale accuracy over the entire flow measuring range.
• have a stainless steel sharp-edged orifice.
• have a weather-tight external construction
• be Lake Monitors No. B_ _ - _ _ _ - _ _

MATERIALS OF CONSTRUCTION: Wetted Components

Component
Aluminum
Brass
Stainless Steel
High-pressure casing, end ports and tapered shaft
Aluminum
Brass
Stainless Steel
Seals
Buna-N (STD), EPR and Viton® or Kalrez®
Buna-N (STD), EPR and Viton® or Kalrez®
Viton® with Teflon® backup, Buna-N, EPR or Kalrez®
Transfer Magnet
Teflon® coated Alnico
Teflon® coated Alnico
Teflon® coated Alnico
Floating Orifice Disk
Stainless Steel
Stainless Steel
Stainless Steel
All other internal parts
Stainless Steel
Stainless Steel
Stainless Steel

MATERIALS OF CONSTRUCTION: Non-Wetted Components

Component
Aluminum
Brass
Steel
Window Tube
Polycarbonate (STD), Pyrex
Polycarbonate (STD), Pyrex
Polycarbonate (STD), Pyrex
Window Seals
Rubber (STD), Teflon®
Rubber (STD), Teflon®
Rubber (STD), Teflon®

Teflon, Viton and Kalrez are registered trademarks of duPont de Nemours & Co.

PERFORMANCE:
• Accuracy: ±4% of full scale over full scale ±2.5% of full scale in the center 1/3 of scale
• Repeatability: ±1% of full scale
• Pressure Differential: < 30 PSIG, consult meter data sheets for exact specifications
• Maximum Operating Temperature: Std: 240ºF (115ºC); Optional: 400ºF (204ºC) and 600ºF (315ºC)
• Maximum Operating Pressure: Aluminum and Brass meters: 3500 PSIG (240 Bar) Stainless Steel meters: 6000 PSIG (410 Bar)
• Flow Range: 0.5-150 GPM (0.2-560 LPM)
MECHANICAL:

DIM
Series 3
Series 4
Series 5
Series 5
A
1-7/8"
(48mm)
2-3/8"
(60mm)
3-1/2"
(90mm)
3-1/2"
(90mm)
B
6-9/16"
(167mm)
7-5/32"
(182mm)
10-1/8"
(258mm)
12-5/8"
(322mm)
Port Sizes
NPTF:1/4",3/8",1/2"
SAE:#6,#8,#10
BSP:3/8",1/2"
NPTF:3/4",1"
SAE:#12,#16
BSP:3/4",1"
NPTF:1-1/4",1-1/2"
SAE:#20, #24
BSP:1-1/4", 1-1/2"
NPTF:2"
SAE:#32
BSP:2"

PRESSURE DIFFERENTIAL VS FLOW RATE:

  