Download PDF File: Data Sheet No. FS4-00

• Choice of Three Port Sizes: Select from 1/2", 3/4" or 1" porting to meet system requirements.
• Easy Maintenance and Cleaning: Has only one moving component, the impeller. Cleaning and maintenance may be performed without removing the sensor from the piping.
• Hermetically Encapsulated Circuitry: Stands up to the harshest environments.
• Transmit Several Thousand Feet: The standard interface is a 2-wire, 4-20mA current loop. Sensor signal may be transmitted on a low cost wire without degradation.
• Connects Directly to Your Flow Monitoring Instruments: Can be connected directly to analog acquisition cards, chart recorders, or other monitoring instruments, without external signal conditioning.
• Simply Plumb and Apply Power: Comes factory calibrated to your flow range specifications.
• Value Pricing: Combined with low cost operation and maintenance, equals better bottom line savings for your operation.
ENGINEERING SPECIFICATIONS:

The Flowstat sensor shall:
• Have only one moving component
• Be calibrated to user specified flow range
• Have a measuring accuracy of 2% of full scale
• Have hermetically encapsulated circuitry
• be Lake Monitors No. C_ _ - _ _ - _ _ for the Current output, and No. P_ _ - _ _ - _ _ for the pulse Output version

MATERIALS OF CONSTRUCTION: Wetted Components

Component
Material
Casing
Stainless Steel
Cover
Stainless Steel
(optional clear polycarbonate)
Seal
Buna-N
(other options available)
Turbine
Acetal Copolymer
Bearing
Iglide 250®
Shaft Stainless Steel

MATERIALS OF CONSTRUCTION: Non-Wetted Components

Component
Material
Encapsulant
Epoxy
Strain Relief
Nylon
Lock Ring
Stainless Steel
Wire Insulation
High Temperature PVC

inglide 250® is a registered trademark of igus®.

PERFORMANCE:
• Measuring Accuracy: ±2% of full scale
• Repeatability: ±0.5% of full scale
• Flow Measuring Range:
1/2" porting:
0.5-15 GPM [2-60 LPM]
3/4"-1" porting: 15-50 GPM [60-200 LPM]
• Temperature Range: 20-225ºF [-7 to 107ºC]
• Pressure Range: to 500 PSIG [34 bar]
w/optional clear cover: to 200 PSIG [14 bar]
• Pressure Differential: See graphs below.
ELECTRONIC SPECIFICATIONS:
4 - 20mA CIRCUIT
Power Requirements
12-35 Vdc
Load Driving Capacity
1150 Ohms max.
Maximum Transmitting Distance
Limited only by wire resistance and supply voltage
LED
Power Indication
Response Time
2 seconds to 90% (step change in flow rate)
Connections
Via 10 ft. (3m.) 22 awg pigtail
Controls 4mA (OFFSET): 20mA (SPAN) Factory Set
Resolution Infinite
Over-Current Limit Self Limiting at 30mA
Other Protection Reverse Polarity
Fail-Safe Indication 4mA

PULSE OUTPUT CIRCUIT
Maximum Voltage
30V DC/AC
Maximum Current
10mA DC/AC
Maximum Power
0.25 Watts
Operate Time (including debounce)
200 Seconds

MECHANICAL:
DIM
1/2" NPTF
3/4" NPTF - 1" NPTF
A
1.94" (49 mm)
3.06" (78mm)
B
1.13" (29 mm)
1.33" (34 mm)
C 2.00" (51 mm) 2.46" (62 mm)
D 2.45" (62 mm) 2.78" (71 mm)
D* 2.60" (66 mm) 2.88" (73 mm)
E 3.70" (94 mm) 5.25" (133 mm)
F 2.63" (67 mm) 3.80" (97 mm)

* Dimension with optional clear polycarbonate cover installed