Armstrong offers a comprehensive range of based mounted pumps designed for a wide variety of applications. These base mounted pumps are single stage, end suction, radially-split centrifugal pumping units featuring self-venting casings to prevent air binding. Armstrong base mounted pumps also include heavy duty bearings that are sealed and lubricated for life, a "back pull-out" bearing frame for easy servicing, and a self-lubricating mechanical seal to prevent liquid seepage. Base mounted pumps are available in bronze fitted, and all iron construction.

Traditional Base Mounted Pump Features:
Back pull-out design
One piece baseplate
Base supported radially-split casing
Flexible coupling with guard
Drain and gauge connections
Cast iron housing, bronze-fitted construction
Value-Added Base Mounted Pump Features
ANSI style centerline discharge casing
ANSI flanged casing
Pre-lubricated and sealed ball bearings
Confined casing gasket
Mechanical seal with silicone carbide seat
Stainless steel shaft sleeve
Dynamically balanced impellers 2-plane where appropriate
OSHA coupling guard
Baseplate designed to ANSI/HI 1.3.5 rigidity standards for freestanding base
Design Features
Traditional Features
Back Pull Out Design
One Piece Baseplate
Base Supported Radially Split Casing
Flexible Coupling, with Guard
Drain and Gauge Connections
Cast Iron Housing, Bronze Fitted Construction
All Iron and Ductile Iron Construction available
Designed, Manufactured, and Inspected to Exacting Standards
Current Design Concepts
ANSI style Centerline Discharge Casing
Large Flow Range
ANSI Flanged Casing
Pre-Lubricated and Sealed Ball Bearings
Confined Casing Gasket
Mechanical Seal with O-Ring Mounted Seat
Stainless Steel Shaft Sleeve
Dynamically Balanced Impellers
Typical Specifications
Circulating Pumps:
Furnish and install, as indicated on the plans and specifications, Armstrong Series 4030 base mounted centrifugal pumps.
The pump shall be single, end suction type with radially split, top center-line discharge, self-venting casing. The casing-to-cover gasket shall be confined on the atmospheric side to prevent blow-out possibility.
Pump construction shall be cast iron, bronze fitted (all iron, all bronze, ductile iron) and shall be fitted with a long-life, product lubricated, drip-tight mechanical seal, with O-ring seat retainer, designed for the specified maximum temperature and pressure.
The shaft shall be fitted with a Stainless Steel shaft sleeve and be supported by two heavy duty ball bearings. The design shall allow Back Pull Out servicing, enabling the complete rotating assembly to be removed without disturbing the casing piping connections.
The pump shall be mounted on a rigid, single piece baseplate, with grouting hole, and connected by flexible coupling, with guard, to a __hp, __Hz, _ph, __volts, __rpm, __enclosure squirrel cage, induction type motor of standard (premium, __%) efficiency and suitable for across-the-line (wye-delta, part wind) starting.
The housing shall be hydrostatically tested to 150% maximum working pressure.
The unit shall be suitable for the conditions shown on the pump schedule.