...at the lowest prices anywhere!
www.cyronix.com
The new
temperature calibration bath range
with interchangeable accessories give greatest ever flexibility;
A complete Calibration Laboratory in One Simple to Use Package
Data Sheets
One Bath
Multi-Functions
From
55°C
below
ambient to
250°C
- large 35mm x 160mm calibration volume
A Metal Block Bath
Fast, convenient, mess free sensor calibration
A Stirred Liquid Bath
Replace the metal insert to calibrate odd shaped sensors and gain enhanced performance
A Stirred Ice Bath
On the VENUS models switch to the stirred ice bath to check and log your reference probe
Black Body Source
Need to calibrate radiation pyrometers? Just add the black body source kit
Surface Sensors
To calibrate surface sensors add the special insert / reference thermometer options
ITS-90 Fixed Points
Need accuracy to +/-0.001°C? Then select one of the ISOCAL-6 F.P. Cells and realize ITS-90 fixed points
Metal Insert
Start with the metal insert then add accessories as needed
Liquid Container
Allows for odd shaped sensors and potentially gives greater performance. With the Venus models you can also use as a stirred ice bath
Magnetic Stirrer: spins exerting centrifugal force
Liquid moves to the side of the container
Combined action causes the...
Flow pattern
Black Body Source
Emissivity greater than 0.995 for the calibration of radiation pyrometers
Surface Sensor Calibrator
Add the special surface kit to allow calibration of surface probes
Fixed Points
The most accurate temperatures are the fixed points of ITS-90, use the ISOCAL-6 F.P. cells to realize fixed points to an accuracy of +/-0.001°C
Data Sheets
ISOCAL-6 Model
Temperature Range
Calibration Volume
Europa
-45°C to 140°C
35 x 160mm
Venus
-35°C to 140°C
35 x 160mm
Calisto
30°C to 250°C
35 x 160mm
Oceanus
-25°C to 110°C
52 x 300mm
Slim Cells for the Isocal