Hanna,HI 9053,HI 9055,K,Type,Thermpcouple,Thermometers

Hanna HI 9053 & 9055 K Type
Thermocouple Thermometers

  Index | Products | About Us | Contact Us | www.eeprocess.com

Products By Type
Air Quality
Air Velocity
Controllers
Data Acquisition Systems
Electrodes & Probes
Equipment Protector Cases
Flow
Gas Monitoring
Humidity & Dewpoint
Level
Light Meters
Miscellaneous
pH Meters
Pressure
Recorders
Sound Level Meters
Stroboscopes
Tachometers
Temperature
Test Calibrators
Test Equipment
Timers
Valves
Weather Stations
 
 

 
Manufacturer

ACR
Almeg Controls
Alnor
Bascom-Turner Instruments
Blue White Industries
Brooklyn Thermometer
Check Line
Cooper
Davis Instruments
Dickson
Dwyer
Extech
Fuji Electric
Hanna Instruments
Han Young
Hedland
Macweld
Miljoco
Monarch Instruments
Noral Temperature Sensors
Ono Sokki
Partlow Process Instruments
Pelican Products
Precision Digital
PSI-Tronix
Raytek
Smar
Test Products International
TES Test Instruments
TPI Test Products Int'l
TSI Incorporated
Versa Gauge
Young Environmental
Zellweger Analytics
 

  Hanna HI 9053 & HI 9055 K Type Thermpcouple Thermometers
HI 9053 & HI 9055 Microprocessor, K-Type Thermocouple Thermometers with Alarms
  • Alarm Functions HI 9053 and HI 9055 provide the user with an advanced alarm capability. Simply set the high and low limits, and an acoustic alarm will alert you if measurements exceed the range.
  • HOLD Function The HOLD button freezes the current reading on the screen, allowing time to record the measurement.
  • High Temperature Range Measurements can be taken from -50 to 950°C or -58 to 1742°F to meet all of your temperature measurement requirements.
  • Specifications

HI 9053 and HI 9055 are microprocessor based thermocouple thermometers that supply the user with reliable readings in the higher temperature ranges. These meters are housed in a rugged ABS casing that protects them for years. The powerful microprocessor provides several added functions to the performance of these meters. HI and LO keys allow the user to recall the highest and lowest readings taken. A MEM HOLD and MR button makes it possible to freeze a reading on the display, and then recall it at a later time. The alarm functions can be set at a high and low point to alert the user in the event of an out-of-range condition. The built-in acoustic alarm is a valuable feature for all engineering tests and process monitoring. The HI 9053 monitors temperature on the Centigrade scale and the HI 9055 measures in the Fahrenheit scale. There are several different K-type thermocouple probes available to meet all of your application needs.

Specifications:

                                           HI 9053                      HI 9055
  Range:                 -50.0 to 150.0°C           -58.0 to 199.8°F or    
                                   -50 to 950°C             -58 to 1742°F    
  Resolution:        0.1°C (-50.0 to 150.0°C)     0.2°F (-58.0 to 199.8°F)
                                   1°C (-50 to 950°C)        1°F (-58 to 1742°F)
  Accuracy ambient  
   temp 77°F/25°C:  ±0.5% Full Scale & ±0.5°C      ±0.5% Full Scale & ±1°F
  Probe:                 HI 766 K-Type Thermocouple series (optional)
  Environment:                      32 to 122°F (0 to 50°C)
  Battery:                              9 volt battery
  Battery Life:                  500 hours of continuous use
  Weight:                             12.4 oz. (350 g) 
  Dimensions:               7.1" x 3.3" x 1.6" (180 x 83 x 40mm)

  Index | Products | About Us | Contact Us | www.eeprocess.com

Hanna HI 9053 & 9055 K Type
Thermocouple Thermometers


Site Designed By Panther Marketing And Design