Hanna,HI 955201,HI 955202,Pt100,Thermometer

Hanna HI 955201 & HI 955202
Pt100 Thermometer

  Index | Products | About Us | Contact Us | www.eeprocess.com

Products By Type
Air Quality
Air Velocity
Controllers
Data Acquisition Systems
Electrodes & Probes
Equipment Protector Cases
Flow
Gas Monitoring
Humidity & Dewpoint
Level
Light Meters
Miscellaneous
pH Meters
Pressure
Recorders
Sound Level Meters
Stroboscopes
Tachometers
Temperature
Test Calibrators
Test Equipment
Timers
Valves
Weather Stations
 
 

 
Manufacturer

ACR
Almeg Controls
Alnor
Bascom-Turner Instruments
Blue White Industries
Brooklyn Thermometer
Check Line
Cooper
Davis Instruments
Dickson
Dwyer
Extech
Fuji Electric
Hanna Instruments
Han Young
Hedland
Macweld
Miljoco
Monarch Instruments
Noral Temperature Sensors
Ono Sokki
Partlow Process Instruments
Pelican Products
Precision Digital
PSI-Tronix
Raytek
Smar
Test Products International
TES Test Instruments
TPI Test Products Int'l
TSI Incorporated
Versa Gauge
Young Environmental
Zellweger Analytics
 

  Hanna HI 955201 & 955202 Pt100 Thermometer
HI 955201 & HI 955202 4-Wire Pt100 Hard Copy of Temperature from -200 to 850°C with 0.1°C Resolution and up to 2 Probes
  • High Resolution From -200.0 to 850.0°C with an incredible 0.1 resolution and unsurpassed accuracy.
  • Versatility Monitoring and printing of readings on up to 2 channels using non-thermal printer paper.
  • Low Power Consumption Low-power printer uses common AA batteries for up to 500 hours of use. A 12VDC battery or battery charger can also power the unit.
  • Specifications

It is often desirable to print and measure temperature in the higher ranges without having to compromise high resolution. For this purpose Hanna has developed the HI 955201 single channel and the HI 955202 dual channel, 4-wire Pt 100 printing thermometers. These thermometers have a resolution of 0.1°C in the range of -200.0 to 850.0. A built-in printer makes it possible to obtain a hard-copy of your temperature measurements taken on 1 or 2 channels, instantly or at determinable intervals. This means you can leave the meter without supervision to record your readings and not have to worry about human error in repeated or prolonged testing. The low-power printer uses plain paper that will not fade over time and is readily available. For field applications, the meter can be plugged into a 12VDC car battery or recharger. The meter is calibrated against a certified standard and is available with a factory calibration certificate (HI 955201C/C & HI 955202C/C). Choose from a variety of optional Pt 100 HI 768 temperature probes.

HI 955201 and HI 955202 are supplied with 5 paper rolls, 4 x 1.5V AA batteries and instruction manual.

Specifications: HI 955201 HI 955202
Range -200 to 850°C
Resolution 0.1°C
Accuracy
(@20°C/68°F)
±0.1°C ± 0.1% of the actual reading
for one year, excluding probe error
Typical EMC
Deviation
±0.5°C
Channels 1 2
Probe 4-wire Pt100 Platinum RTD (alpha = 0.00385)
Printer Low-power impact type-belt; 14 characters per line; 38mm plain paper
Printing Intervals 1, 2, 5, 10, 30, 60, 120 and 180 minutes
Power Supply 4 x 1.5V AA batteries / approx. 500 hours with 60’ printing interval. Auto shut-off after 5 minutes of non-use. Power socket for 12VDC
Environment 32 to 122°F (0 to 50°C); RH 95%
Dimensions 8.7 x 3.2 x 2.6" (220 x 82 x 66 mm)
Weight 18 oz.. (500 g)


  Index | Products | About Us | Contact Us | www.eeprocess.com

Hanna HI 955201 & HI 955202
Pt100 Thermometer


Site Designed By Panther Marketing And Design