| DESCRIPTION
Versa
Gauge Bi-Metal Thermometers are available in 3” (75 mm) and 5”
(125 mm) dials. Versa offers three different models; 90o Back
Connection, Fully Adjustable or Bottom connection models. Also,
available is the 2” (50 mm) dial equipped with a 90o back connection.
Versa Gauge Bi-Metal Thermometers are available in oF/oC dual
scale, Fahrenheit (F) only or Celsius (C) only temperature scales.
Connections are standard 1/2” NPT on 3” (90 mm) and 5” dials,
and standard 1/4” NPT on 2”(50 mm) dial sizes. Glass lens is standard
with optional acrylic lens available up to 300oF (150oC). Available
in various stem lengths up to 72” (183 mm). The stem and bezel
is 304 stainless steel, with a sleek, grey, dish shaped design
for easy viewing. The Bi-Metal Thermometers are hermetically sealed
per ASME B40.3 and have an external recalibrator-reset screw to
ensure accuracy . The bi-metallic element is super sensitive helix
coil. Accuracy is ± 1% of full scale value.
Available
options include: thermowells, thread size, dial diameters, glass,
acrylic or safety glass lens, tags, special dials, and 316 wetted
parts.
Technical
Drawing
| APPLICATIONS |
|
Versatile
industrial thermometer that can be used in many industrial
applications..
- Tanks
-
Vats
-
Ducts
-
Ovens
-
HVAC applications.
(Acrylic
lens available for Food applications.) Can be liquid-filled
up to 300F(150C) for high vibration applications.
|
| SPECIFICATIONS: |
| DIAL:
|
2”
(50mm), 3” (75mm), 4” (100mm) and 5” (125mm) dials, aluminum
with black markings, dish shaped |
| Case:
|
AISI
304 stainless steel |
| Ring:
: |
AISI
304 stainless steel |
| Lens: |
Glass
standard, hermetically sealed |
| Pointer: |
Brass,
painted black |
| Movement: |
Bi-metallic
coil |
| Stem:
|
AISI
304 stainless steel, center back, bottom or fully adjustable
angle configurations (note 2” (50mm) dial only available with
center back connection |
| Connection:
|
1/4”
NPT standard for 2” (50mm) dial 1/2” NPT standard for 3” (75mm),
4” (100mm) and 5” dials (125mm) |
| Recalibrator:
|
Standard
|
| Maximum
Operating Pressure: |
125
psi (861 kPa) (Recommended thermowell use for pressures above
125 psi) |
| Ambient
Temperature: |
Maximum
248oF (120oC) |
| Operating
Temperature: |
Recommended
maximum 75% of full scale value |
| Accuracy:
|
±
1% full scale |
|