Pulsation,Dampeners,ACCU,PULSE

Pulsation Dampeners ACCU-PULSE
Primary Fluid Systems Inc.

  Home    About Us     History    Products    Forms    Contact Us
Products By Type
ACCUDRAW®
Calibration Cylinders
PVC & PP Cylinders
Glass Cylinders
ACCUDRAW® Literature
Calibration Instructions
Cad Drawings
Dimensional Drawings
 
ACCU-PULSE
Pulsation Dampeners
Pulsation Dampeners
ACCU-PULSE Literature
Installation Instructions
Specification Sheets
Cad Drawings
Dimensional Drawings
 
ACCU-VENT
Degassing Valves
Degassing Valves
ACCU-VENT Literature
Instruction Manual
Cad Drawings
Dimensional Drawings

 
Corporation Stops
Corporation Stops
Literature
Installation Instructions
CAD Drawings
Dimensional Drawings

 
Injection Quills
PFS Injection Quills
Injection Quill Literature
Installation Instructions
CAD Drawings
Dimensional Drawings

 
TOP VALVE
Back Pressure Valves
Back Pressure Valves
Literature
Installation Instructions
Flanged Valves
Engineering Spec's
Cad Drawings
Dimensional Drawings

 
Engineering Spec's
Engineering Spec's
 
Metering Pump Accessories
Metering Pump Access.
General Literature
 
CAD .dwg Files &
Dimensional Drawings Library
CAD .dwg Files
Dimensional Drawings
 
Web Site In
Other Languages
Francais
  Littérature Générale
 
Espanol
  Literatura General
 
English
 
General Literature
 
Online Catalog
Email
Email Us
 
Web Site
www.primaryfluid.com
 
PFS Movie
PFS Movie
PFS Flash Intro
 
Specializing In
Metering Pump
Accessories


North American
Toll Free:
1 800 776-6580


 
Web Site Tools
 

 

 
  Pulsation Dampeners ACCU-PULSE

Pulsation Dampeners ACCU-PULSE
Developed to remove pulsating flows from positive displacement pumps.

• increase system efficiency and pump life
• decrease maintenance and costs
• protect pipes, meters, valves and instrumentation from pulsation and vibration
• ensure meter accuracy, longevity and repeatability
• reduce pressure fluctuations and diaphragm wear
• prevent foaming and splashing


Standard Features:

  • lightweight, compact design
  • 150 psi rating
  • easy in-line maintenance
  • 2 year warranty
  • 3/8", 3/4" and 1" pipe connections; 10 & 85 Cubic in.
  • PP, PVC, PVDF, 316 S/S, Alloy 20 and Hastelloy C

Sizing Guide

The following formula sizes are for use on diaphragm, piston and plunger type metering pumps.

Required Sizing Information:


V = volume per pump stroke in cubic inches
K = type of pump (K factor)
P = mean operating pressure
D = allowable pressure fluctuation as a percentage ( +/- from mean)
n = exponent for type of gas used (Nitrogen = 0.714; Air = 1.0)

V - Volume per stroke calculations:

1)

Gallons per minute / strokes per minute = gallons per stroke
Gallons per stroke X 231 cubic inches per gallon = cubic inch per stroke or
2)
.7854 X (inch bore diameter)2 X inch stroke length = cubic inch per stroke


K - Type of pump:

 
Single Acting
Double Acting

Simplex

.60
.25

Duplex

.25
.15

Triplex

.13
.06

Quadruplex

.10
.06

P - Operating Pressure (Mean):
Allowable pressure fluctuations:
Minimum pressure Pmin = P - (P X D)
Maximum pressure Pmax = P + (P X D)

Formula

V x K ( P / Pmin )
1 - (P / Pmax)
= Cubic inch capacity required

Ordering Information

eg. Part # API-PVC-E-1

AP - I - PVC - E - 1

AP
= ACCU-PULSE
I
= Series Capacity
PVC
= Body Material
E
= Bellows Material
1
= Size

Series
Capacity
Body Material
Bellows Material
Size

I

10 cu in

PP= polypropylene

N = neoprene

1 = 3/8"npt(f) series 1

IF

4 cu in

PVC = polyvinylchloride

B = buna-N

2= 3/4"npt(f) series II (std)

II

85 cu in

PVDF =
poylvinyldene fluoride

H = hypalon

3 = 1"npt(f) series II (no charge)

IIF

36 cu in

S/S =
316 stainless steel

E = EPDM

4 = 2"npt(f) series III (std)

III

370 cu in

ALL20 = alloy 20

V = viton

 

IIIF

175 cu in

HAST = hastelloy C

T = Teflon

 