Technical Data | Ordering Data | Downloads | Back
Our Solid Core Current Transformers convert a monitored AC current to a proportional DC voltage of 0 to 5 Volts.
Applications:They are used to monitor motors, pumps, conveyors, machine tools and any electrical load where an analogue representation is required over a range of currents. All models are CSA approved and UL listed.
Description:The A100 comprises a current transformer, range selector, rectifier-filter, and scaling circuit. Each sensor has three basic user selectable ranges. The 0-5 VDC output is available on two 6-32 screw terminals.
Solid Core Current Transformers - Technical Data| Size: | 2.18"
H x 3.53" W x 0.94" D Mounting centres of 3.08". The through hole is 0.75" for up to #2/0 cable. |
| Operating temperature: | -50°C to +65°C. |
| Case: | ABS (Meets UL flammability rating 94V-0) |
| Accuracy: | ± 1% of full scale when loaded with 1 megohm. |
| Repeatability: | ± 1% full scale |
| Frequency: | Calibrated for 50-60 Hz and within ± 2% from 20-100 Hz. |
| Response time: | 100 msec (10 to 90%) |
| Ripple: | Less than 10 millivolts |
| Model | Range | Jumper Amps | Max Cont Amps | Max 6s ON 15s OFF | Max 1s ON 15s OFF |
| 100-1 | 1 to 10 |
None
|
80
|
125
|
250
|
| 2 to 20 |
Mid
|
110
|
150
|
300
|
|
| 5 to 50 |
High
|
175
|
215
|
400
|
|
| 100-2 | 10/100 |
None
|
200
|
300
|
600
|
| 15/150 |
Mid
|
300
|
450
|
800
|
|
| 20/200 |
High
|
400
|
500
|
1000
|
| Model 100-1 |
for ranges of 1 to 10, 2 to 20, and 5 to 50 amps full scale. |
| Model 100-2 |
for ranges of 10 to 100, 15 to 150, and 20 to 200 amps full scale. Output is zero VDC between 0 amps and beginning of range and then proportional to input. |
All files are
in PDF format and may be read with Adobe
Acrobat Reader
Technical
Data | Ordering Data | Downloads | Back | Top