Technical Data | Installation & Operation | Ordering Data | Downloads | Back
Pressure Transmitters - Stainless Steel
Model 4340
Pressure Transmitters determine the pressures in liquids and gases and convert these pressures to an electrical signal. The 4340 features compact construction, an integral amplifier, large output signal and extensive medium compatablility. The design provides a 1/2% accurate, economical transmitter that can operate accurately over a wide temperature range with corrosion resistance.
Pressure
Transmitters - Stainless Steel - Technical
Data
| Wetted parts / Case: | Stainless steel 316L & 446/ s/s 304 & polycarbonate |
| Ambient/Medium temperature: | -40...+85°C |
| Pressure Connection: | 1/4" NPT |
| Supply Voltage: | 12...30VDC (incl. peaks), 20 mA max. loading |
| Output: | 2-wire 4 to 20 mA, max load = U-12V/0.02A |
| Accuracy: | 1% |
| Errors: | load < 0.15%, ambient temperature 0.05%/°C |
| Hysteresis: | 0.2% max (linear characteristic) |
| Overload limit: | 200% full scale |
| Enclosure: | IP65 (NEMA 4) |
| Response time: | 10 msec |
| Operating position: | unrestricted |
Pressure
Transmitters - Stainless Steel - Installation
& Operation
Operation
The ceramic coated steel diaphragm sensing element deflects under pressure. This deflection is transmitted to a thick-film resistor network mounted on the ceramic layer which causes the connected pair of opposite resistances to either expand or contract. This produces a positive or negative resistance change proportional to the pressure. A constant voltage supply to the bridge followed by a differential amplifier converts the signal to a magnified proportional voltage output.
This is added to a temperature dependent reference voltage and electronically compensated for temperature drift. The signal is finally converted via a voltage controlled current source to a standard 4-20 mA signal.
CautionAlways use a wrench on the stainless steel fitting to tighten the transmitter into the process. Using the body of the transmitter to tighten it by hand can cause permanent damage.
Installation![]() |
|
Pressure
Transmitters - Stainless Steel - Ordering
Data
| Range | Order # | ||
| -30" Hg | ... | 15psi | 4341-3015 |
| 0 | ... | 30psi | 4341-30 |
| 0 | ... | 60psi | 4341-60 |
| 0 | ... | 100psi | 4341-100 |
| 0 | ... | 160psi | 4341-160 |
| 0 | ... | 250psi | 4341-250 |
| 0 | ... | 500psi | 4341-500 |
Pressure Transmitters - Stainless Steel - Downloads
All files are
in PDF format and may be read with Adobe
Acrobat Reader
Technical
Data | Installation & Operation | Ordering
Data | Downloads | Back | Top
of page