- reference
values and tolerances to EN 60 751
- wire-wound
versions in glass and ceramic
- thin-film
versions
- as Pt100
and Pt1000
- temperature
ranges between -200 and +800 °C
- applications:
heating, air conditioning and ventilation, food processing, climate
chambers, power plants, general industrial
- for fabrication
into resistance thermometers
- simple
replacement without recalibration through standardised reference values
|
 |
|
Wire
Temperature Sensors to EN 60 751
|
|
Platinum-ceramic
versions
- for temperatures
from -200 to +600ºC or +800 °C
- as single
or twin temperature sensor
- as Pt100
- no hysteresis
under alternating temperatures
- sizes:
dia. 1.5 to 2.6 mm, length 15 to 30 mm
|
 |
 |
Thin-Film
Temperature Sensors to EN 60 751
|
Platinum-chip
versions with connecting wires
- for temperatures
from -50 to +500 °C
- as Pt100,
and Pt1000
- special
selections available
- sizes:
width 2mm, length 4 mm, thickness 1.1 mm
|
 |
Platinum-chip
versions, SMD style
- for temperatures
from -50 to +130 °C
(170ºC with compatable mounting surface)
- as Pt100
and Pt1000
- for automatic
large-scale assembly
- supplied
in blister belt for automatic insertion
- wrap-around
contact with diffusion blockage
- size:
1208 and 806 format (603 format in development)
|
 |