Programmable Temperature Controllers
Programmable
Temperature Controllers
Programmable Temperature Controllers are microprocessor
based program controllers which stores a maximum of 256
segments in 16 patterns (16 segments per pattern ) and
are the ideal instrument for measuring temperature, controlling
heaters, and logging temperature data.
Programmable Temperature Controllers are
compact 96 mm (4" ) Square DIN size unit that features
a unique touch key panel which allows the display section
of the front panel to be used not only for setting but
also for data entry.
Programmable
Temperature Controllers Features:
-
Advanced ramp and soak
-
Large memory storage - 16 patterns/16
segments
-
Autotuning learning function
-
Easy programming with unique touch key
-
Compact size 96 x 96 mm
-
Audible verification of key operation
-
Setting lock function for security operation
mode
-
Mode indicators RESET RUN FIX MAN SET
enable easy monitoring
-
Program pattern card simplifies program
pattern checking
-
3 year warranty
Programmable
Temperature Controllers Specifications:
INPUT
-
Thermocouple - Type J,K,T,E,B,R,S,N (selectable)
-
RTD - PT 100 ohm (DIN or JIS)
-
Linear - -10-60mV Configurable input other
voltage or current.
-
Display - in temperature or engineering
units
-
Outputs - Single output with 2 optional
independent alarms - Heating and/or cooling outputs
with 2 optional alarms
-
Relay - SPST relay rated 3A, 240V maximum
resistive load
-
Pulsed Voltage - 32VDC, 20mA maximum ohms
-
Current - 4-20mA, 0-20mA maximum load
500 ohms
-
Voltage - 0-10V minimum load 500K ohms
-
Alarms - 8 selectable modes each alarm
- SPST relay(s) rated 2A, 240V maximum resistive load.
CONTROL FEATURES
-
Temperature Range - Selectable Set Point:
-1999-31820ºF/-1128-1750ºC
-
Alarm Set Point - Full Range Adjustable
-
Control Modes - Controls can be configured
as On/Off Proportional(P), Proportional with manual
reset, Proportional/Integral(PI) Proportional Derivative(PD),
Proportional/Integral/Derivative(PID), Heating and Cooling
Proportional Band:O-100% of span
-
Integral (Reset) - 0-3600 seconds
-
Derivative (Rate) - 0-1000 seconds
-
Anti-Reset Wind-up. Inhibits integral
action outside of proportional band.
-
Cooling - Adjustable deadband from -10
to + 10% of cooling proportional band
-
Manual Mode - Configurable as open loop
control should sensor no longer function
-
Cycle Time - 0-120 seconds
-
Sensor Break Protection. Configurable
status of control and alarms
-
Control Action - Selectable-Direct action
for cooling Reverse action for heating
INDICATION
Selectable decimal
placement for normal or high resolution display
-
Example - 0000, 000.0, 00.00 or 0.000
-
F/C - Selectable with 2 LED indicators
-
Sample Rate - 250 milliseconds
-
Data Retention - 10 years (EEPROM)
-
Control Stability - + - 0.15% of full
scale
-
Accuracy - +/-0.25% of range: +/-1ºC
or 0.5ºC in high resolution
-
Cold Junction Compensation - 0.1 % ambient
-
External Resistance - 100 ohms maximum
-
Common Mode Rejection - 120dB
-
Normal Mode Rejection - 60dB
-
Input Impedance - 10M ohms
-
Operating Temperature - 14-122ºF-10-50ºC
-
Humidity - 0-90% RH (non-condensing)
-
Insulation - 20M ohm minimum (5OOVDC)
-
Breakdown - 2OOVAC, 5O/60Hz 1 minute
-
Vibration - 10-55Hz amplitude 1 mm
-
Shock - 200m/c (20g)
|