Frigid-X
Cabinet Panel Coolers and Cabinet Enclosure Coolers
for electronic control panels provide a low cost method
of both purging and cooling electrical and electronic
control panels by using a stainless steel vortex
tube to create cold air from ordinary compressed
air.
Unlike many of our competitors all of
the our Frigid-X Cabinet Panel Coolers
and Cabinet Enclosure Coolers are stainless steel, not
just the vortex tube for longer life and flexible use.
Frigid-X Cabinet Panel Coolers and Cabinet
Enclosure Coolers are compact and can be installed in
minutes through a standard electrical knockout. There
are virtually no moving parts.
Frigid-X Cabinet Panel Coolers
and Cabinet Enclosure Coolers are ideal for all NEMA
Type 12 (IP52), NEMA Type 3R (IP14) and NEMA Type 4-4X
(IP56) rated panels (NEMA Type 4-4X - US
patent number 8,616,010. Other countries: Patented or
Patent Pending). Prevent downtime due to overheating
electric and electronic control panels and cabinets.
Frigid-X
Cabinet Panel Coolers And Cabinet Enclosure Coolers
- Advantages:
-
Low in cost compared to others
-
No moving parts
-
Eliminate fans, blowers and filters
-
Quiet
-
Superior design and performance
-
Maintenance free operation
-
Mounts in a standard electrical knockout
-
Made of durable stainless steel and
metal arts - no cheap plastic parts
-
Cooling capacities to 2800 BTU/hour
per unit
-
Maintain NEMA Type 12 (IP52), NEMA
Type 3R (IP14) and NEMA Type 4-4X (IP56) integrity
-
Control and stabilize the temperature
and humidity inside the enclosure
-
No CFC's or HCFC's
-
Eliminate circuit drift, nuisance
drifting and dirt
-
Provide washdown protection (NEMA
Type 4-4X (IP56)
Frigid-X
Cabinet Panel Coolers and Cabinet Enclosure Coolers
- Applications:

Note: Always question
non-approved units used on electrical enclosures to assure
that your panels are not damaged by inferior products.

Nex Flow offers a High Temperature
Warning Sticker free with every Frigid-X
Panel Cooler purchased for the air conditioning
of electrical and electronic control panels. High
temperature inside a control panel can be damaging
to internal equipment and lead to unplanned shutdown
of factory operations. The label provides for
an effective warning with a color change indicator
to ORANGE and a danger warning with a color change
indicator to RED. Color change is reversible so
when the temperature problem is corrected, the
label can continue to be used indefinitely. While
it is a qualitative measurement only, it provides
an ideal cautionary monitoring of possible temperature
problems within a control panel. Extra High Temperature
Warning Stickers can be purchased.
PART NUMBER: 69600
|
Four
Types of Frigid-X
Cabinet
Panel Coolers To Choose From:
-
Frigid-X Cabinet
Panel Coolers NEMA Type 12 (IP-52)
For Electronic Control Panels for General use in industrial
environments where no direct liquid spray is applied
to the unit. Stainless steel construction to hold
up in corrosive environments.
-
Frigid-X Cabinet
Panel Coolers NEMA Type 3R (IP-14)
For Electronic Control Panels for Outdoor Use. Stainless
steel to hold up to rain, snow, humidity and general
outdoor use.
-
Frigid-X Panel
Coolers NEMA Type 4-4X (IP-56)
For Electronic Control Panels - splash resistant,
for use in wash down environments as well as outdoor
use. Unique patent pending design for secure water
tight protection. Stainless steel for food service
and corrosive environments. Stainless steel also provides
for long life in wet environments and for outdoor
use. US patent number 8,616,010. Other countries:
Patented or Patent Pending
-
Frigid-X Panel
Coolers NEMA Type 4-4X-316L
(IP-56) For Electronic Control Panels
all external exposed surfaces are of 316L and ideal
for pharmaceutical industry and extreme corrosive
environments where 303/304 stainless steel is not
adequate. As with the NEMA Type 4-4x units, the cooler
is splash resistant, for use in wash down environments
as well as outdoor use. Unique patent pending design
for secure water tight protection. 316L Stainless
steel for pharmaceutical grade, food service and extreme
corrosive environments. Stainless steel also provides
for long life in wet environments and for outdoor
use. US patent number 8,616,010. Other countries:
Patented or Patent Pending
Cabinet Enclosure
Cooler ( Panel Coolers Air Conditioner) - All Metal Parts,
Stainless Steel Body, Quiet - Under 70dBA, Tests Show
Frigid-X Constantly Quieter Than Competition!
Frigid-X
Cabinet Panel Coolers and Cabinet Enclosure Coolers -
Operation:
Filtered, compressed air enters the cabinet
enclosure cooler and through the vortex tube component.
The air is split into two streams, one hot and one cold.
The muffled hot air from the vortex tube
is expelled through the top of the air conditioner. The
cold air is directed into the enclosure through the cold
air distribution hose. Hot air inside the enclosure rises
and exits to atmosphere via the air exhaust at a slight
positive pressure. The enclosure is both purged and cooled
with clean air. No outside air enters the enclosure.
Specifications:
Contact Nex Flow for assistance in sizing
cabinet enclosure cooler - Frigid-X series.
Below see Sizing Specifications.
|
MODEL
NO.
|
VERSION
|
BTU/Hr.
cooling*
(WATTS)
|
|
61008A
|
NEMA
Type 12 (IP-52) Continuous Operation
|
580
(170)
|
|
61015A
|
NEMA
Type 12 (IP-52) Continuous Operation
|
1100
(322)
|
|
61025A
|
NEMA
Type 12 (IP-52) Continuous Operation
|
1800
(527)
|
|
61030A
|
NEMA
Type 12 (IP-52) Continuous Operation
|
2100
(615)
|
|
61040A
|
NEMA
Type 12 (IP-52) Continuous Operation
|
2900
(849)
|
| |
|
|
|
63008A
|
NEMA
Type 12 (IP-52) on-off control
|
580
(170)
|
|
63015A
|
NEMA
Type 12 (IP-52) on-off control
|
1100
(322)
|
|
63025A
|
NEMA
Type 12 (IP-52) on-off control
|
1800
(527)
|
|
63030A
|
NEMA
Type 12 (IP-52) on-off control
|
2100
(615)
|
|
63040A
|
NEMA
Type 12 (IP-52) on-off control
|
2900
(849)
|
| |
|
|
|
61008R
|
NEMA
Type 3R (IP-14) Continuous Operation
|
580 (170)
|
|
61015R
|
NEMA
Type 3R (IP-14) Continuous Operation
|
1100
(322)
|
|
61025R
|
NEMA
Type 3R (IP-14) Continuous Operation
|
1800
(527)
|
|
61030R
|
NEMA
Type 3R (IP-14) Continuous Operation
|
2100
(615)
|
|
61040R
|
NEMA
Type 3R (IP-14) Continuous Operation
|
2900
(849)
|
| |
|
|
|
63008X
|
NEMA
Type 3R (IP-14) on-off control
|
580
(170))
|
|
63015X
|
NEMA
Type 3R (IP-14) on-off control
|
1100
(322)
|
|
63025X
|
NEMA
Type 3R (IP-14) on-off control
|
21800
(527)
|
|
63030X
|
NEMA
Type 3R (IP-14) on-off control
|
2100
(615)
|
|
63040X
|
NEMA
Type 3R (IP-14) on-off control
|
2900
(849)
|
| |
|
|
|
61108X
|
NEMA
Type 4-4X (IP-66) Continuous Operation
|
580
(170)
|
|
61115X
|
NEMA
Type 4-4X (IP-66) Continuous Operation
|
1100
(322)
|
|
61125X
|
NEMA
Type 4-4X (IP-66) Continuous Operation
|
1800
(527)
|
|
61130X
|
NEMA
Type 4-4X (IP-66) Continuous Operation
|
2100
(615)
|
|
61140X
|
NEMA
Type 4-4X (IP-66) Continuous Operation
|
2900
(849)
|
| |
|
|
|
63108X
|
NEMA
Type 4-4X (IP-66) on-off control
|
580
(170))
|
|
63115X
|
NEMA
Type 4-4X (IP-66) on-off control
|
1100
(322)
|
|
63125X
|
NEMA
Type 4-4X (IP-66) on-off control
|
21800
(527)
|
|
63130X
|
NEMA
Type 4-4X (IP-66) on-off control
|
2100
(615)
|
|
63140X
|
NEMA
Type 4-4X (IP-66) on-off control
|
2900
(849)
|
| |
|
|
| 60115X |
316
L Stainless Steel NEMA Type 4-4X (IP-66) on-off
control (customer supplies own filter)** |
1100
(322) |
| 60125X |
316
L Stainless Steel NEMA Type 4-4X (IP-66) on-off
control (customer supplies own filter)** |
21800
(527) |
| 60130X |
316
L Stainless Steel NEMA Type 4-4X (IP-66) on-off
control (customer supplies own filter)** |
2100
(615) |
| 60140X |
316
L Stainless Steel NEMA Type 4-4X (IP-66) on-off
control (customer supplies own filter)** |
2900
(849) |
| |
|
|
|
** In 316 environments normally customers will have
special filtration systems for such environments
already. |
| |
|
|
*Cooling effect based on 95ºF temperature inside
cabinet, 100 PSIG (6.9 BAR) compressor inlet pressure,
and 70ºF (21ºC) inlet temperature. BTU/hr.
figures rounded to nearest 100 BTU/hr (1 WATT).
All Continuous Operation models include the cooling
unit, filter with auto drain and cold air distribution
kit.
All On-Off control units include the cooling unit,
filter with auto drain, cold air distribution kit, solenoid
valve and thermostat.

Use
Our Side Mounts For Tight Spaces
Cabinet
Cooling Solutions With Frigid-X Cabinet Panel
Coolers are normally mounted on the top of the enclosure
but if space does not permit, you can use our Side Mount
Kit. Made of stainless steel for NEMA Type 12 (IP52),
NEMA Type 3R (IP14) and NEMA Type 4-4X (IP56) environments,
they are designed for use with all Nex Flow Cabinet
Cooling Solutions With Frigid-X Cabinet Panel
Coolers. Two sizes are available, one for coolers 85CFM
and under capacity and the other forlarger sizes. Slim
design to minimize space even when mounted on the side
of a panel.
Easy mount Side Mount Kit is available
for smal and medium size panel coolers to allow mounting
to the side of an enclosure if space prevents top mounting.
It is a "plug and play" system.
|