HE-H8 | 150mm Emitt./Rec.HE 80mm Emitt./Rec.H8 |
Operating
voltage 10-30Vdc NPN or PNP NO or NC |
| - LED
status indicator (only HE) - Very high switching frequency (100KHz and 50KHz) - Dimensions extreme reduced (miniature housing M8) - Protection degree IEC IP67 - Complete protection against electrical damages - Red light with visible spot (only HE) |
|||
![]() |
HM-MM | 1m Emitt./Rec.HM 4mEmitt./Rec.MM 2m Retro reflective 2m Polarized 100-200mm Diffuse reflection |
Operating
voltage 10-30Vdc NPN or PNP NO or NC |
| - LED
status indicator - Very high switching frequency (10KHz only HM) - Types with connectors M8 and M12 - Focusing set to detect small objects up to ø 0.25mm (only HM) - Protection degree IEC IP67 - Complete protection against electrical damages - Red light with visible spot (only HM) |
|||
![]() |
SS-SP | 3 and 8m Emitt./Rec. 2m Retroreflective or Polarised 100-200-400mm Diffuse reflection 50-100-200mm Direct with regulator (SS) |
Operating
voltage 10-30Vdc NPN or PNP NO or NC |
| - LED
status indicator - Types with connector M12 - Protection degree IEC IP67 (IP65 for types SS with sensitivity adjustment) - Check availability for all types of emitters – receivers - Complete protection against electrical damages - Types with polarised red light |
|||
![]() |
SS-SP |
4m Retroreflective
without regulation 3m Polarised without regulation 50-100-200-400mm Diffuse Reflection without regulation 50-100-200-400-800mm Diffuse Reflection with regulation |
Operating voltage
10-30Vdc NPN or PNP NO/NC selectable |
| - Side
sensitivity adjustment - Led status indicator - Protection degree IEC IP67 - Complete protection against electrical damages |
|||
![]() |
MS-MP | 16 and 32m Emitt./Rec. 4m Retroreflective 3m Polarised 100-200-400mm Direct 50-100mm Background suppression (MP) |
Operating
voltage 10-30Vdc DECOUT® (NPN, PNP, NO, NC) |
| - Photoelectric
Sensor cylindrical M18 - LED status indicator - Type with connector M12 - Protection degree IEC IP67 - Check availability for all types of emitters - receivers (only MS) - complete protection against electrical damages |
|||
![]() |
MV-MQ | 16 and 32m Emitt./Rec. 4m Retroreflective 3m Polarised 100-200-400mm Direct 50-100mm Background suppression (MQ) |
Operating
voltage 10-30Vdc TRIAC NO or NC |
| - Photoelectric
Sensor cylindrical M18 - LED status indicator - Type with connector M12 - Protection degree IEC IP67 |
|||
![]() |
SA | 6m Retroreflective 3m Polarised 150-400-1000mm Direct 12-25-50mm fixed focus |
Operating
voltage 10-30Vdc NPN or PNP NO / NC |
| - LED
status indicator - Sensitivity adjustment - Selectable output: NO/NC - Types with connectors M12 - Protection degree IEC IP65 - Complete protection against electrical damages |
|||
![]() |
MT | 100m Emitt./Rec. | Operating
voltage 10-30Vdc NPN or PNP NO / NC |
| - Photoelectric
Sensor cylindrical M30 - 3 LED indicator for easy installation and alignment - Selectable output NO/NC - Protection degree IEC IP67 - Complete protection against electrical damages - Alarm output and emitter check |
|||
![]() |
PS | 4m Emitt./Rec. 2m Retroreflective 100-200mm Direct |
Operating
voltage 10-30Vdc NPN or PNP NO / NC |
| - Photoelectric
Sensor, rectangular in small dimensions - LED indicator - Sensitivity adjustment - Types with connector M12 - Protection degree IEC IP65 - Protection against short circuits, polarity reversal |
|||
![]() |
BS-BV | 8m Emitt./Rec. 2,5m Polarised 100-200-400-1600mm Direct |
Operating
voltage 10-30 VDC (BS)- DECOUT® (NPN/PNP/NO/NC) 20-253 VAC (BV)-TRIAC |
| - Rectangular
Photoelectric Sensor - LED indicator - Sensitivity adjustment - Types with connector M12 - Protection degree IEC IP65 - Complete protection against electrical damages |
|||
![]() |
QX | 8m Emitt./Rec. 4m Retroreflective 2,5m Polarised 300mm Direct |
Operating
voltage 10-30Vdc NPN / PNP NO or NC |
| - Miniature
Photoelectric Sensor with high performance for objects min.
2mm - Axial optics or to 90° - Selectable output: PNP/NPN - Sensitivity adjustment - Types with connectors M8 - Protection degree IEC IP65 - complete protection against electrical damages |
|||
![]() |
RX | 16 and 32m Emitt./Rec. 12m Retroreflective 6m Polarised 1-2m Direct 300-1000 Background suppression |
Operating
voltage 10-30 Vdc 20-253 Vac |
| - Universal
Rectangular Photoelectric Sensor DC/AC-DC - Timer function delay on, delay off, one shot (0,1 - 10sec.) - Selectable output: PNP/NPN - Sensitivity adjustment - Relay exit or DECOUT® - Output NO/NC selectable by dip-switch - Protection degree IEC IP65 |
|||
![]() |
SX |
50-600mm Background suppression |
Operating
voltage 10-30 Vdc PNP/NPN |
| - Rectangular
Photoelectric Sensor - Sensitivity adjustment - Visible red light for easy alignment - Exits antivalent NO and NC - M12 plug-in exit - Protection degree IP67 |
|||
![]() |
TX |
6m Polarised 2m Direct 100-1500mm Background suppression |
Operating
voltage 24 Vdc 20-264 Vac/Vdc |
| - Rectangular
Photoelectric Sensor - Sensitivity adjustment - Totally protected against electrical damages - Types in DC with antivalent exits NO and NC - Types in AC with relais exit SPDT - Plug exit |
|||
![]() |
UR | 8m Emitt./Rec. (with DGE and DGR ø10mm sensors) and M12 | Operating
voltage 24 Vdc, 110Vac or 220Vac |
| - Alignment
(stability), supply voltage, alarm and output state LED indicators - Selectable output: NO/NC - Sensitivity adjustment x1 o x2 (distance 30 or 60m) - double timer with independent adjustments - Protection degree IEC IP68 |
|||
|
|
161
Lakeshore Road, East
Tel: 905 274-2555 Fax: 905 274-5552 Toll Free: 1-800-567-1041 |
Photoelectric Sensors