Accumulators,ACCU,PULSE,Pulsation,Dampeners

Accumulators
ACCU-PULSE Pulsation Dampeners


  Home | About Us | Contact | New Products

Pumps
 ARO Pumps
 Caster Pumps
 Flux Pumps
 Gidding & Lewis
 Grundfos

 Pulsafeeder

 Promag
 Viking Pump
  
Calibration Cylinders
 Primary Fluid Systems Inc
  
Corporation Stops
 Primary Fluid Systems Inc
  
Flow Meters
 Burkert Contromatic
 Hays
 Kobold
 
Lake Monitors

  
Injection Quills
 Primary Fluid Systems Inc
  
Mixers
 Midwest Mixing
 TAH Industries
 
Pulsation Dampeners
 ARO Pumps
 
Primary Fluid Systems Inc
  
Pressure
 Winters Thermoguages
 
Strainers
 Hayward Industrial
 
Valves
 Burkert Contromatic
 Dynalfluid 2000
 Primary Fluid Systems Inc
 
Web Site & Email
 Web Site
 Email Us
 
Web Site Tools
 



 
  Accumulators ACCU-PULSE Pulsation Dampeners

Accumulators ACCU-PULSE Pulsation Dampeners
Developed to remove pulsating flows from positive displacement pumps.

• increase system efficiency and pump life
• decrease maintenance and costs
• protect pipes, meters, valves and instrumentation from pulsation and vibration
• ensure meter accuracy, longevity and repeatability
• reduce pressure fluctuations and diaphragm wear
• prevent foaming and splashing



Accumulators ACCU-PULSE Pulsation Dampeners
Standard Features:

  • lightweight, compact design
  • 150 psi rating
  • easy in-line maintenance
  • 2 year warranty
  • 3/8", 3/4" and 1" pipe connections; 10 & 85 Cubic in.
  • PP, PVC, PVDF, 316 S/S, Alloy 20 and Hastelloy C

Accumulators ACCU-PULSE Pulsation Dampeners
Pulsation Dampeners Sizing Guide

The following formula sizes Pulsation Dampeners for use on diaphragm, piston and plunger type metering pumps.

Required Sizing Information:


V = volume per pump stroke in cubic inches
K = type of pump (K factor)
P = mean operating pressure
D = allowable pressure fluctuation as a percentage ( +/- from mean)
n = exponent for type of gas used (Nitrogen = 0.714; Air = 1.0)

V - Volume per stroke calculations:

1)

Gallons per minute / strokes per minute = gallons per stroke
Gallons per stroke X 231 cubic inches per gallon = cubic inch per stroke or
2)
.7854 X (inch bore diameter)2 X inch stroke length = cubic inch per stroke


K - Type of pump:

 
Single Acting
Double Acting

Simplex

.60
.25

Duplex

.25
.15

Triplex

.13
.06

Quadruplex

.10
.06

P - Operating Pressure (Mean):
Allowable pressure fluctuations:
Minimum pressure Pmin = P - (P X D)
Maximum pressure Pmax = P + (P X D)

Formula

V x K ( P / Pmin )
1 - (P / Pmax)
= Cubic inch capacity required

Accumulators ACCU-PULSE Pulsation Dampeners
Ordering Information


eg. Part # API-PVC-E-1

AP - I - PVC - E - 1

AP
= ACCU-PULSE
I
= Series Capacity
PVC
= Body Material
E
= Bellows Material
1
= Size

Series
Capacity
Body Material
Bellows Material
Size

I

10 cu in

PP= polypropylene

N = neoprene

1 = 3/8"npt(f) series 1

IF

4 cu in

PVC = polyvinylchloride

B = buna-N

2= 3/4"npt(f) series II (std)

II

85 cu in

PVDF =
poylvinyldene fluoride

H = hypalon

3 = 1"npt(f) series II (no charge)

IIF

36 cu in

S/S =
316 stainless steel

E = EPDM

4 = 2"npt(f) series III (std)

III

370 cu in

ALL20 = alloy 20

V = viton

 

IIIF

175 cu in

HAST = hastelloy C

T = Teflon

 


  Home | About Us | Contact | New Products

Accumulators
ACCU-PULSE Pulsation Dampeners


Site Designed By Panther Marketing & Design