MVS-2027, 2067 and 2200 SERIES
The MVS-2027, 2067 and 2200 Machine Vision Strobe
systems produce short duration, high intensity light pulses for
industrial vision applications. When coupled to a CCD/CID
camera system the MVS-2027, 2067 or 2200 "freezes motion", eliminates blur from the camera image and enhances image quality.
The three models are identical in every respect except the MVS-2067 and MVS-2200 provide higher flash repetition rates at lower flashlamp input energies than the MVS-2027. Each unitis contained in a robust industrial enclosure with two connectors, one for the input power line and the other for signal level inputs.
The Xenon light output is focused onto a port configured for mounting one end of a Fiber Optic Bundle so that the light can be projected to an area remote from the instrument. Various fiber optic bundles, nose pieces and adapters are available to interface the fiber cable to the strobe enclosure.
Do you need a more powerful strobe?
click here
| Optical Specifications |
. |
|
MVS-2027 |
MVS-2067 |
MVS-2200 |
| Spectral Bandwidth
|
350 - 1100 + nm |
350 - 1100 + nm |
300 - 1100 + nm |
| Photometric Output (1) |
6 lumen-sec |
3 lumen-sec |
1.2 lumen-sec |
| Radiometric light output (1) |
50 mJ |
25 mJ |
10 mJ |
| Flash rate per second |
20 max |
60 max |
200 max |
| Input energy per flash (2) |
2.16 joules |
0.72 joules |
0.18 joules |
| Light output pulse duration (3) |
20 µsec |
12 µsec |
5 µsec |
| Flashlamp life |
>108 flashes maintaining > 70% light output |
| Fiber bundle diameter |
0.2 to 0.5 inches (5 to 13 mm) |
| Electrical Specifications |
. |
| Line input voltage (4) |
115/230 Vac ± 10%, 50/60 Hz
(factory set at 115 Vac) |
| Input current |
1.2 amps rms max. |
| Intensity control input (5) |
2 - 6 Vdc (Vref : Vlamp = 1 : 100) |
| Trigger Input |
. |
| Trigger |
5 Volt pulse into 4N36 opto-isolator with 150
ohm nominal series resistor |
| Pulse duration (1) |
10 to 100 µsec |
| Environmental Specifications |
. |
| Operating temperature |
-10 to + 104ºF (-23 to +43ºC) |
| Shock and vibration |
1.5 G, 5 to 200 Hz per MIL-STD-810C |
Notes:
1) Measured through a 0.5 inch (13 mm) aperture at light output port.
2) Energy at 600 Vdc (E = ½CV2). Discharge capacitor values are: MVS-2020 - 12 µfd, MVS-2060 - 4µfd, MVS-2200 - 1µfd.
3) Approximate values at 1/3 peak.
4) Specify 230 Vac operation if desired.
5) Intensity may be changed by adjusting voltage on discharge capacitor from 200 - 600 Vdc.