DC
Input Alarm Trip |
Looptracker® LED Alarm Status LEDs Push to Test/Reset Lifetime Warranty | ||||
|
Model | Input | Output | Features | Data & Applications | Photo |
|
API
1000 G DC Input Single Alarm Trip Specify Input, Alarm Type & Power
API 1020 G | Factory
Configured 0-100 mVDC to 0-600 VDC 0-1 mADC to 0-1 ADC | 1 or 2
Field Adjustable 7A SPDT Alarm Relays | Hot-Swappable
Plug-In Design Looptracker® LED for Input Alarm Status LEDs Push to Test Uses 11-Pin Socket |
Data Sheet | |
|
API
1005 G DC Input Single Alarm Trip with Loop Power Supply Specify Alarm Type & Power
API 1025 G | 4-20 mADC | 1 or 2
Field Adjustable 7A SPDT Alarm Relays | Hot-Swappable
Plug-In Design Looptracker® LED for Input Alarm Status LEDs Push to Test/Reset 18 V Loop Power Supply Uses 11-Pin Socket |
Data Sheet Reference Info Alarm Terminology Deadband Relay Protection & EMI Suppression |
|
|
API
1040 G DC Input Single Alarm Trip with Non-Isolated DC-DC Transmitter with Loop Power Supply Specify Input, Output, Alarm Type & Power | Factory
Configured 0-100 mVDC to 0-100 VDC ±100 mVDC - ±10VDC 0-1 mADC to 0-1 ADC | 1 Field
Adjustable 7A SPDT Alarm Relay & Factory Configured Others available 0-1V 0-5V 1-5V 0-10V ±5V ±10V, 0-20mA 4-20mA | Hot-Swappable
Plug-In Design Looptracker® LED Alarm Status LEDs Push to Test/Reset 18 V Loop Power Supply Uses 11-Pin Socket |
Data Sheet Applications DC Transmitter with Alarm Over-Temperature Alarm with Retransmission Reference Info Alarm Terminology Deadband Relay Protection & EMI Suppression | ![]() |
|
API
1080 G Field Selectable DC Input Single Alarm Trip with Loop Power Supply Specify Power | Min: 0-50
mVDC Max: ±10 VDC Min: 0-1 mADC Max: 0-20 mADC | 1 Field
Adjustable & Configurable 7A SPDT Alarm Relay | Hot-Swappable
Plug-In Design Minuteman Setup Looptracker® LED Alarm status LED Push to Test/Reset 18 V Loop Power Supply Uses 11-Pin Socket |
Data Sheet Range Settings Help Sheet Applications Auto-Ranging Flow Meter Flow Meter Auto Select Reference Info Alarm Terminology Deadband Relay Protection & EMI Suppression | ![]() Socket Sold Separately |
|
API
1080 DIN Field Selectable DC Input Single Alarm Trip with Loop Power Supply Specify Power | Min: 0-50
mVDC Max: ±10 VDC Min: 0-1 mADC Max: 0-20 mADC | 1 Field
Adjustable & Configurable 7A SPDT Alarm Relay | Minuteman
Setup Looptracker® LED Alarm status LED Push to Test/Reset 12 V Loop Power Supply DIN package 22.5 mm W Universal Power Operation |
Data Sheet
Applications Pumping System High Pressure Shutdown Reference Info Alarm Terminology Deadband Relay Protection & EMI Suppression | |
|
API
1090 G Field Selectable DC Input Dual Alarm Trip with Loop Power Supply Specify Power | Min: 0-50
mVDC Max: ±10 VDC Min: 0-1 mADC Max: 0-20 mADC | 2 Field
Adjustable & Configurable 7A SPDT Alarm Relays | Hot-Swappable
Plug-In Design Minuteman Setup Looptracker® LED Alarm status LEDs Push to Test/Reset 18 V Loop Power Supply Uses 11-Pin Socket | Data
Sheet Range Settings Help Sheet Applications Chemical Plant Reference Info Alarm Terminology Deadband Relay Protection & EMI Suppression | ![]() Socket Sold Separately |
|
API
1090 DIN Field Selectable DC Input Dual Alarm Trip Specify Power
API 1090 DIN DD | Min: 0-50
mVDC Max: ±10 VDC Min: 0-1 mADC Max: 0-20 mADC | 2 Field
Adjustable & Configurable 7A SPDT Alarm Relays | Minuteman
Setup Looptracker® LED Alarm status LEDs Push to Test/Reset 12 V Loop Power Supply DIN package 22.5 mm W Universal Power Operation |
Data
Sheet Applications Pumping System High/Low Pressure Alarm Reference Info Alarm Terminology Deadband Relay Protection & EMI Suppression | |
|
Tel:
1-800-794-5883
|
Email: sales@mod-tronic.com
|
Fax:
1-800-830-7122
|
|
|
DC