DC Input Alarm Trips Click
Button For Details:
|
|||||
|---|---|---|---|---|---|
| Model | Input | Output | Additional Features | Power | |
| API 1000 G |
| DC
Voltage or Current Specify Range | 1
Field Adjustable Alarm Specify Alarm Type | 115VAC
Standard Opt. 230VAC, 9-30VDC | |
| API 1020 G | DC
Voltage or Current Specify Range | 2
Field Adjustable Alarms Specify Alarm Type | 115VAC
Standard Opt. 230VAC, 9-30VDC | ||
| API 1005 G |
| 4-20 mA | 1
Field Adjustable Alarm Specify Alarm Type | 18V Loop Supply | 115VAC
Standard Opt. 230VAC, 9-30VDC |
| API 1025 G | 4-20 mA | 2
Field Adjustable Alarms Specify Alarm Type | 18V Loop Supply | 115VAC
Standard Opt. 230VAC, 9-30VDC | |
| API 1040 G |
| DC
Voltage or Current Specify Range | 1
Field Adjustable Hi/Lo Alarm DC Voltage or Current Specify Range | Non-Isolated
DC Transmitter 18V Loop Supply | 115VAC
Standard Opt. 230VAC, 9-30VDC |
|
API 1080
G 1080G Ranges 1080G Help |
| DC
Voltage or Current Field Selectable Ranges | 2
Field Adjustable Alarms Field Selectable Alarm Action | 18V
Loop Supply Socket Sold Separately | 115VAC
Standard Opt. 230VAC, 9-30VDC |
| API 1080 DIN |
| DC
Voltage or Current Field Selectable Ranges | 2
Field Adjustable Alarms Field Selectable Alarm Action | 12V
Loop Supply DIN pack | 80-265VAC 48-300VDC |
|
API 1090
G 1090G Ranges 1090G Help |
| DC
Voltage or Current Field Selectable Ranges | 2
Field Adjustable Alarms Field Selectable Alarm Action | 18V
Loop Supply Socket Sold Separately | 115VAC
Standard Opt. 230VAC, 9-30VDC |
| API 1090 DIN |
| DC
Voltage or Current Field Selectable Ranges | 2
Field Adjustable Alarms Field Selectable Alarm Action | 12V Loop Supply | 80-265VAC 48-300VDC |
| API 1090 DD | DC
Voltage or Current Field Selectable Ranges | 2
Field Adjustable Alarms Field Selectable Alarm Action | 12V
Loop Supply DIN pack | 9-30VDC | |
|
DC
- DC Transmitters Click
Button For Details:
| |||||
| Model | Input | Output | Additional Features | Power | |
| API 4010 G | | DC
Voltage or Current Specify Range | DC
Voltage or Current Specify Range | 18V Loop Supply | 115VAC
Standard Opt. 230VAC, 9-30VDC |
| API 4050 G | DC
Voltage or Current Specify Range Narrow Input Span | DC
Voltage or Current Specify Range | 18V Loop Supply | 115VAC
Standard Opt. 230VAC, 9-30VDC | |
| API 4300 G | | DC
Voltage or Current Factory Set Range | DC
Voltage or Current Specify Range | Full
Isolation 18V Loop Supply | 115VAC
Standard Opt. 230VAC, 9-30VDC |
| API 4310 G | DC
Voltage or Current Specify Range Narrow Input Range | DC
Voltage or Current Specify Range | Full
Isolation 18V Loop Supply | 115VAC
Standard Opt. 230VAC, 9-30VDC | |
|
API 4380
G 4380G Ranges 4380G Help |
| DC
Voltage or Current Field Selectable Ranges | DC
Voltage or Current Field Selectable Ranges | Full
Isolation 18V Loop Supply | 115VAC
Standard Opt. 230VAC, 9-30VDC |
|
API 4380
GHV3 4380GHV3 Ranges | DC
Voltage or Current Field Selectable Ranges High Voltage Input to ±200 VDC | DC
Voltage or Current Field Selectable Ranges | Full
Isolation 18V Loop Supply | 115VAC
Standard Opt. 230VAC, 9-30VDC | |
|
API 4380
DIN 4380DIN Help |
| DC
Voltage or Current Field Selectable Ranges | DC
Voltage or Current Field Selectable Ranges | Full
Isolation 12V Loop Supply DIN pack | 80-265VAC 48-300VDC |
|
API 4380
DD 4380DIN Help | DC
Voltage or Current Field Selectable Ranges | DC
Voltage or Current Field Selectable Ranges | Full
Isolation 12V Loop Supply DIN pack | 9-30VDC | |
|
API 4385
G 4385G Ranges | | DC
Voltage or Current Field Selectable Ranges | DC
Voltage or Current Field Selectable Ranges | Full
Isolation True Offset Non-Interacting Controls 18V Loop Supply | 115VAC
Standard Opt. 230VAC, 9-30VDC |
|
DPI HV-DC DPI HV-DC Ranges |
| High
Voltage DC 0-100VDC to 0-1200VDC | DC
Voltage or Current Field Selectable Ranges | Full
Isolation DIN pack | 115VAC
Standard Opt. 230VAC, 9-30VDC |
| LPI-1 | | 4-20 mA | 4-20 mA | Full Isolation | Loop Powered |
| LPI-2 | Two 4-20 mA | Two 4-20 mA | Full Isolation | Loop Powered | |
| DPI-2 | | Two 4-20 mA | Two 4-20 mA | Full
Isolation DIN pack | Loop Powered |
|
Thermocouple
Input Click
Button For Details:
| |||||
| Model | Input | Output | Additional Features | Power | |
| API 1200 G | | J,
K, T, E Thermocouple Specify Type & Range | 1
Field Adjustable Alarm Specify Alarm Type | 115VAC
Standard Opt. 230VAC, 9-30VDC | |
| API 1220 G | J,
K, T, E Thermocouple Specify Type & Range | 2
Field Adjustable Alarms Specify Alarm Types | 115VAC
Standard Opt. 230VAC, 9-30VDC | ||
|
API 4000 G 4000G Ranges 4000G Help | | J,
K, T, E, R, S Thermocouple Most RTDs & Resistance Elements Field Selectable Type & Range |
DC Voltage
or Current |
Full Isolation | 115VAC
Standard Opt. 230VAC, 9-30VDC |
| API 4100 G | | J,
K, T, E Thermocouple Specify Type & Range |
DC Voltage
or Current | 115VAC
Standard Opt. 230VAC, 9-30VDC | |
| API 4130 GL | J,
K, T, E Thermocouple Specify Type & Range |
DC Voltage
or Current | Full Isolation | 115VAC
Standard Opt. 230VAC, 9-30VDC | |
|
LP 300 LP300 Help |
| J,
K, T, E Thermocouple Field Selectable Type & Range |
4-20 mA | Full Isolation | Loop Powered |
|
RTD
Input Click
Button For Details:
| |||||
| Model | Input | Output | Additional Features | Power | |
| API 1400 G | | 10
ohm to 2000 ohm RTDs Factory Set Type & Range | 1
Field Adjustable Alarm Specify Alarm Type | 115VAC
Standard Opt. 230VAC, 9-30VDC | |
| API 1420 G | 10
ohm to 2000 ohm RTDs Specify Type & Range | 2
Field Adjustable Alarms Specify Alarm Types | 115VAC
Standard Opt. 230VAC, 9-30VDC | ||
|
API 4000
G 4000G Ranges 4000G Help | | Most
RTDs & Resistance Elements J, K, T, E, R, S Thermocouple Field Selectable Type & Range |
DC Voltage
or Current |
Full Isolation |
115VAC
Standard |
| API 4001 G | | 10
ohm to 2000 ohm RTDs Specify Type & Range | DC
Voltage or Current Specify Range | 115VAC
Standard Opt. 230VAC, 9-30VDC | |
| API 4001 GL | 10
ohm to 2000 ohm RTDs Specify Type & Range | DC
Voltage or Current Specify Range |
Full Isolation | 115VAC
Standard Opt. 230VAC, 9-30VDC | |
| API 4001 G SA-B | | Two
100 ohm 0.00385 curve RTDs For Differential Temperature Factory Set, Can Be Field Calibrated | DC
Voltage or Current Specify Range |
Full Isolation | 115VAC
Standard Opt. 230VAC, 9-30VDC |
|
LP 200 LP200 Help |
| 100 ohm 0.00385 curve RTD | 4-20 mA |
Full Isolation | Loop Powered |
|
Loop-Powered
Isolators Click
Button For Details:
| |||||
| Model | Input | Output | Additional Features | Power | |
| LPI-1 |
| 4-20 mA | 4-20 mA | Full Isolation | Loop Powered |
| LPI-2 | Two 4-20 mA | Two 4-20 mA | Full Isolation | Loop Powered | |
| DPI-2 |
| Two 4-20 mA | Two 4-20 mA | Full
Isolation DIN pack | Loop Powered |
| LP
200 LP200 Help |
| 100 ohm 0.00385 curve RTD | 4-20 mA |
Full Isolation | Loop Powered |
| LP
300 LP300 Help |
| J,
K, T, E Thermocouple Field Selectable Type & Range |
4-20 mA | Full Isolation | Loop Powered |
|
Potentiometer
Input Click
Button For Details:
| |||||
| Model | Input | Output | Additional Features | Power | |
| API 1800 G |
| 0-100 ohm to 0-1 Mega ohm Potentiometer | 1
Field Adjustable Alarm Specify Alarm Type | 115VAC
Standard Opt. 230VAC, 9-30VDC | |
| API 1820 G | 0-100 ohm to 0-1 Mega ohm Potentiometer | 2
Field Adjustable Alarms Specify Alarm Types | 115VAC
Standard Opt. 230VAC, 9-30VDC | ||
| API 4003 G | | 0-100 ohm to 0-1 Mega ohm Potentiometer | DC
Voltage or Current Specify Range | 115VAC
Standard Opt. 230VAC, 9-30VDC | |
| API 4003 G I | 0-100 ohm to 0-1 Mega ohm Potentiometer | DC
Voltage or Current Specify Range |
Full Isolation | 115VAC
Standard Opt. 230VAC, 9-30VDC | |
| API 4008 G |
| 0-100 ohm to 0-1 Mega ohm Potentiometer | DC
Voltage or Current Field Selectable Ranges |
Full Isolation | 115VAC
Standard Opt. 230VAC, 9-30VDC |
|
AC Input Modules Click
Button For Details:
| |||||
| Model | Input | Output |
Additional Features | Power | |
| API 1600 G | | AC
Voltage or Current Specify Range | 1
Field Adjustable Alarm Specify Alarm Type | 115VAC
Standard Opt. 230VAC, 9-30VDC | |
| API 1620 G | AC
Voltage or Current Specify Range | 2
Field Adjustable Alarms Specify Alarm Type | 115VAC
Standard Opt. 230VAC, 9-30VDC | ||
| API 6010 G | | AC
Voltage or Current Specify Range |
DC Voltage
or Current | Full
Isolation 18V Loop Supply | 115VAC
Standard Opt. 230VAC, 9-30VDC |
| API 6010 G 5A |
| AC
Current (up to 5 A) Specify Range |
DC Voltage
or Current |
Full
Isolation | 115VAC
Standard Opt. 230VAC, 9-30VDC |
|
API 6380
G 6380G Ranges 6380G Help |
| AC
Voltage or Current Field Selectable Ranges |
DC Voltage
or Current | Full
Isolation 18V Loop Supply | 115VAC
Standard Opt. 230VAC, 9-30VDC |
|
API 6380
G S 6380GS Ranges 6380GS Help | AC
Voltage or Current (True RMS) Field Selectable Ranges |
DC Voltage
or Current |
True
RMS AC | 115VAC
Standard Opt. 230VAC, 9-30VDC | |
|
Strain
Gauge/Bridge Input Click
Button For Details:
| |||||
| Model | Input | Output |
Additional Features | Power | |
| API 1500 G |
| Strain
Gauge, Bridge, Load Cell Specify Input Span | 1
Field Adjustable Alarm Specify Alarm Type | Adjustable Excitation | 115VAC
Standard Opt. 230VAC, 9-30VDC |
| API 1520 G | Strain
Gauge, Bridge, Load Cell Specify Input Span | 2
Field Adjustable Alarms Specify Alarm Type | Adjustable Excitation | 115VAC
Standard Opt. 230VAC, 9-30VDC | |
| API 4051 G |
| Strain
Gauge, Bridge, Load Cell Specify Input Span |
DC Voltage
or Current | Adjustable Excitation | 115VAC
Standard Opt. 230VAC, 9-30VDC |
|
API 4058
G 4058G Ranges 4058G Help | | 1
to 4 Strain Gauges, Bridges, Load Cells Field Selectable Ranges |
DC Voltage
or Current | Adjustable Excitation | 115VAC
Standard Opt. 230VAC, 9-30VDC |
|
API 4059
G 4059G Help 4059G Ranges |
| 1
to 4 Strain Gauges, Bridges, Load Cells Field Selectable Ranges |
DC Voltage
or Current |
Full
Isolation | 115VAC
Standard Opt. 230VAC, 9-30VDC |
| API SUM-xxx |
| Summing
Assembly Board for 1 to 4 Strain Gauges, Bridges, Load Cells |
DC Voltage
or Current | Individually
Adjustable Excitation & Signal Trim Optional SS Housing | 115VAC
Standard Opt. 230VAC, 9-30VDC |
|
Frequency
Modules
Click
Button For Details:
| |||||
| Model | Input | Output | Additional Features | Power | |
| API 1700 G | | 10
Hz to 20 KHz Specify Input Span | 1
Field Adjustable Alarm Specify Alarm Type | 115VAC
Standard Opt. 230VAC, 9-30VDC | |
| API 1720 G | 10
Hz to 20 KHz Specify Input Span | 2
Field Adjustable Alarms Specify Alarm Type | 115VAC
Standard Opt. 230VAC, 9-30VDC | ||
| API 7010 G | | 10
Hz to 20 KHz Specify Input Span |
DC Voltage
or Current | Full Isolation | 115VAC
Standard Opt. 230VAC, 9-30VDC |
|
API 7500
G 7500G Ranges 7500G Help |
| DC
Voltage or Current Field Selectable Ranges |
0-100
Hz to 0-30 KHz | Full
Isolation 18V Loop Supply | 115VAC
Standard Opt. 230VAC, 9-30VDC |
|
API 7500
G SS 7500SS Ranges | DC
Voltage or Current Field Selectable Ranges |
0-1
Hz to 0-300 Hz | Full
Isolation 18V Loop Supply | 115VAC
Standard Opt. 230VAC, 9-30VDC | |
|
API 7580
G 7580G Ranges 7580G Help | | 100
Hz to 30 KHz Field Selectable Ranges |
DC Voltage
or Current | Full
Isolation 18V Loop Supply | 115VAC
Standard Opt. 230VAC, 9-30VDC |
|
Math Modules
& Valve Positioner Click
Button For Details:
| |||||
| Model | Input | Output | Additional Features | Power | |
|
API 4400
G thru API 4408 G |
| Up
to 4 DC Voltage or Current Inputs Specify Ranges |
DC Voltage
or Current | Addition,
Subtraction, Averaging Modules Isolated | 115VAC
Standard Opt. 230VAC, 9-30VDC |
| API 4440 G |
| DC
Voltage or Current Specify Range |
DC Voltage
or Current |
Square
Root Extraction | 115VAC
Standard Opt. 230VAC, 9-30VDC |
| API 3200 G | | DC
Voltage or Current Specify Range 100 ohm - 100 kohm Feedback Pot |
2 SPST Relays | Valve
/ Actuator Positioner / Controller | 115VAC
Standard Opt. 230VAC, 9-30VDC |
|
Loop
Power Supplies Click
Button For Details:
| |||||
| Model | Input | Output | Additional Features | Power | |
| API 9046 |
|
115VAC Standard |
Regulated DC Voltage |
Isolated |
115VAC Standard |
| API 9046 CH |
115VAC Standard |
Regulated DC Voltage |
Isolated |
115VAC Standard | |
|
Module
Accessories & Options Click
Button For Details:
| |||||
|
Power
Options, Sockets & Housings |
|
Socket
Data Sheet 8-Pin, 11-Pin Standard and Finger Safe Sockets | |||
|
Current
Sensors Click
Button For Details:
| |||||
| Model | Input | Output | Additional Features | Power | |
|
CTX-ACR AC Current Transmitters |
| 0-2
Amps to 0-200 Amps AC | 4-20 mA | True
RMS Isolated Output | Loop Powered |
|
CTX-ACR-3S
& 4S High AC Current Transmitters |
| 0-375
Amps to 0-2000 Amps AC | 4-20 mA | True
RMS Isolated Output | Loop Powered |
|
CTX-DC DC Current Transmitters |
| 0-50
Amps to 0-400 Amps DC | 4-20 mA | Isolated Output | 20-50
VDC or 22-38VAC |
|
CS-AC AC Current Switches |
| 1.5-150 Amps AC | 0.15 Amp SSR | LED
Status Indicator NC or NO Models | Self Powered |
|
CS-DC DC Current Switches |
| 5-100 Amps DC | 0.3
Amp SSR or 5 Amp Relay | LED
Power Indicator LED Status Indicator | 20-28
VAC/DC or 12 VAC/DC |
|
2RL/5RL/7RL/8RL AC Current Transformers | | 600
VAC 50:5 to 1600:5 Ratios | Proportional to Input | 24"
Leads 4 Sizes | Self Powered |
|