Absolute,Process,Instruments,Inc
Quality • Performance • Price • 1972-2003


Absolute Process Instruments, Inc.

  DC Input Alarm Trips  Click Button For Details: 

Model Input Output Additional Features Power
API 1000 G DC Voltage or Current
Specify Range
1 Field Adjustable Alarm
Specify Alarm Type
  115VAC Standard
Opt. 230VAC, 9-30VDC
API 1020 G DC Voltage or Current
Specify Range
2 Field Adjustable Alarms
Specify Alarm Type
  115VAC Standard
Opt. 230VAC, 9-30VDC
API 1005 G 4-20 mA 1 Field Adjustable Alarm
Specify Alarm Type
18V Loop Supply 115VAC Standard
Opt. 230VAC, 9-30VDC
API 1025 G 4-20 mA 2 Field Adjustable Alarms
Specify Alarm Type
18V Loop Supply 115VAC Standard
Opt. 230VAC, 9-30VDC
API 1040 G DC Voltage or Current
Specify Range
1 Field Adjustable Hi/Lo Alarm
DC Voltage or Current
Specify Range
Non-Isolated DC Transmitter
18V Loop Supply
115VAC Standard
Opt. 230VAC, 9-30VDC
API 1080 G
1080G Ranges
1080G Help
DC Voltage or Current
Field Selectable Ranges
2 Field Adjustable Alarms
Field Selectable Alarm Action
18V Loop Supply
Socket Sold Separately
115VAC Standard
Opt. 230VAC, 9-30VDC
API 1080 DIN DC Voltage or Current
Field Selectable Ranges
2 Field Adjustable Alarms
Field Selectable Alarm Action
12V Loop Supply
DIN pack
80-265VAC
48-300VDC
API 1090 G
1090G Ranges
1090G Help
DC Voltage or Current
Field Selectable Ranges
2 Field Adjustable Alarms
Field Selectable Alarm Action
18V Loop Supply
Socket Sold Separately
115VAC Standard
Opt. 230VAC, 9-30VDC
API 1090 DIN DC Voltage or Current
Field Selectable Ranges
2 Field Adjustable Alarms
Field Selectable Alarm Action
12V Loop Supply 80-265VAC
48-300VDC
API 1090 DD DC Voltage or Current
Field Selectable Ranges
2 Field Adjustable Alarms
Field Selectable Alarm Action
12V Loop Supply
DIN pack
9-30VDC

  DC - DC Transmitters  Click Button For Details: 

Model Input Output Additional Features Power
API 4010 G DC Voltage or Current
Specify Range
DC Voltage or Current
Specify Range
18V Loop Supply 115VAC Standard
Opt. 230VAC, 9-30VDC
API 4050 G DC Voltage or Current
Specify Range
Narrow Input Span
DC Voltage or Current
Specify Range
18V Loop Supply 115VAC Standard
Opt. 230VAC, 9-30VDC
API 4300 G DC Voltage or Current
Factory Set Range
DC Voltage or Current
Specify Range
Full Isolation
18V Loop Supply
115VAC Standard
Opt. 230VAC, 9-30VDC
API 4310 G DC Voltage or Current
Specify Range
Narrow Input Range
DC Voltage or Current
Specify Range
Full Isolation
18V Loop Supply
115VAC Standard
Opt. 230VAC, 9-30VDC
API 4380 G
4380G Ranges
4380G Help
DC Voltage or Current
Field Selectable Ranges
DC Voltage or Current
Field Selectable Ranges
Full Isolation
18V Loop Supply
115VAC Standard
Opt. 230VAC, 9-30VDC
API 4380 GHV3
4380GHV3 Ranges
DC Voltage or Current
Field Selectable Ranges
High Voltage Input to ±200 VDC
DC Voltage or Current
Field Selectable Ranges
Full Isolation
18V Loop Supply
115VAC Standard
Opt. 230VAC, 9-30VDC
API 4380 DIN
4380DIN Help
DC Voltage or Current
Field Selectable Ranges
DC Voltage or Current
Field Selectable Ranges
Full Isolation
12V Loop Supply
DIN pack
80-265VAC
48-300VDC
API 4380 DD
4380DIN Help
DC Voltage or Current
Field Selectable Ranges
DC Voltage or Current
Field Selectable Ranges
Full Isolation
12V Loop Supply
DIN pack
9-30VDC
API 4385 G
4385G Ranges
DC Voltage or Current
Field Selectable Ranges
DC Voltage or Current
Field Selectable Ranges
Full Isolation
True Offset
 Non-Interacting Controls
18V Loop Supply
115VAC Standard
Opt. 230VAC, 9-30VDC
DPI HV-DC
DPI HV-DC Ranges
High Voltage DC
0-100VDC to 0-1200VDC
DC Voltage or Current
Field Selectable Ranges
Full Isolation
DIN pack
115VAC Standard
Opt. 230VAC, 9-30VDC
LPI-1 4-20 mA 4-20 mA Full Isolation Loop Powered
LPI-2 Two 4-20 mA Two 4-20 mA Full Isolation Loop Powered
DPI-2 Two 4-20 mA Two 4-20 mA Full Isolation
DIN pack
Loop Powered

  Thermocouple Input   Click Button For Details:  

Model Input Output Additional Features Power
API 1200 G J, K, T, E Thermocouple
Specify Type & Range
1 Field Adjustable Alarm
Specify Alarm Type
   115VAC Standard
Opt. 230VAC, 9-30VDC
API 1220 G J, K, T, E Thermocouple
Specify Type & Range
2 Field Adjustable Alarms
Specify Alarm Types
   115VAC Standard
Opt. 230VAC, 9-30VDC
API 4000 G
4000G Ranges
4000G Help
 
J, K, T, E, R, S Thermocouple
Most  RTDs & Resistance Elements
Field Selectable Type &  Range

DC Voltage or Current
Field Selectable Ranges

Full Isolation

115VAC Standard
Opt. 230VAC, 9-30VDC
API 4100 G J, K, T, E Thermocouple
Specify Type & Range

DC Voltage or Current
Field Selectable Ranges

  115VAC Standard
Opt. 230VAC, 9-30VDC
API 4130 GL J, K, T, E Thermocouple
Specify Type & Range

DC Voltage or Current
Field Selectable Ranges

Full Isolation 115VAC Standard
Opt. 230VAC, 9-30VDC
LP 300
LP300 Help
J, K, T, E Thermocouple
Field Selectable Type & Range

 4-20 mA

Full Isolation  Loop Powered

  RTD Input  Click Button For Details: 

Model Input Output Additional Features Power
API 1400 G 10 ohm to 2000 ohm RTDs
Factory Set Type & Range
1 Field Adjustable Alarm
Specify Alarm Type
   115VAC Standard
Opt. 230VAC, 9-30VDC
API 1420 G 10 ohm to 2000 ohm RTDs
Specify Type & Range
2 Field Adjustable Alarms
Specify Alarm Types
  115VAC Standard
Opt. 230VAC, 9-30VDC
API 4000 G
4000G Ranges
4000G Help
 
Most  RTDs & Resistance Elements
J, K, T, E, R, S Thermocouple
Field Selectable Type & Range

DC Voltage or Current
Field Selectable Ranges

Full Isolation

115VAC Standard
Opt. 230VAC, 9-30VDC

API 4001 G 10 ohm to 2000 ohm RTDs
Specify Type & Range
DC Voltage or Current
Specify Range
   115VAC Standard
Opt. 230VAC, 9-30VDC
API 4001 GL 10 ohm to 2000 ohm RTDs
Specify Type & Range
DC Voltage or Current
Specify Range

Full Isolation

 115VAC Standard
Opt. 230VAC, 9-30VDC
API 4001 G SA-B Two 100 ohm 0.00385 curve RTDs
For Differential Temperature
Factory Set, Can Be Field Calibrated
DC Voltage or Current
Specify Range

Full Isolation

 115VAC Standard
Opt. 230VAC, 9-30VDC
LP 200
LP200 Help
100 ohm 0.00385 curve RTD 4-20 mA

Full Isolation

Loop Powered

  Loop-Powered Isolators   Click Button For Details: 

Model Input Output Additional Features Power
LPI-1 4-20 mA 4-20 mA Full Isolation Loop Powered
LPI-2 Two 4-20 mA Two 4-20 mA Full Isolation Loop Powered
DPI-2 Two 4-20 mA Two 4-20 mA Full Isolation
DIN pack
Loop Powered
LP 200
LP200 Help
100 ohm 0.00385 curve RTD 4-20 mA

Full Isolation

Loop Powered
LP 300
LP300 Help
J, K, T, E Thermocouple
Field Selectable Type & Range

 4-20 mA

Full Isolation  Loop Powered

  Potentiometer Input  Click Button For Details: 

Model Input Output Additional Features Power
API 1800 G 0-100 ohm to 0-1 Mega ohm Potentiometer 1 Field Adjustable Alarm
Specify Alarm Type
   115VAC Standard
Opt. 230VAC, 9-30VDC
API 1820 G 0-100 ohm to 0-1 Mega ohm Potentiometer 2 Field Adjustable Alarms
Specify Alarm Types
   115VAC Standard
Opt. 230VAC, 9-30VDC
API 4003 G 0-100 ohm to 0-1 Mega ohm Potentiometer DC Voltage or Current
Specify Range
   115VAC Standard
Opt. 230VAC, 9-30VDC
API 4003 G I 0-100 ohm to 0-1 Mega ohm Potentiometer DC Voltage or Current
Specify Range

Full Isolation

 115VAC Standard
Opt. 230VAC, 9-30VDC
API 4008 G 0-100 ohm to 0-1 Mega ohm Potentiometer DC Voltage or Current
Field Selectable Ranges

Full Isolation

 115VAC Standard
Opt. 230VAC, 9-30VDC

  AC Input Modules  Click Button For Details: 

Model Input Output

Additional Features

Power
API 1600 G AC Voltage or Current
Specify Range
1 Field Adjustable Alarm
Specify Alarm Type
  115VAC Standard
Opt. 230VAC, 9-30VDC
API 1620 G AC Voltage or Current
Specify Range
2 Field Adjustable Alarms
Specify Alarm Type
  115VAC Standard
Opt. 230VAC, 9-30VDC
API 6010 G AC Voltage or Current
Specify Range

DC Voltage or Current
Specify Range

Full Isolation
18V Loop Supply
115VAC Standard
Opt. 230VAC, 9-30VDC
API 6010 G 5A AC Current (up to 5 A) 
Specify Range

DC Voltage or Current
Specify Range

Full Isolation
Socket & 25W Shunt

115VAC Standard
Opt. 230VAC, 9-30VDC
API 6380 G
6380G Ranges
6380G Help
AC Voltage or Current
Field Selectable Ranges

DC Voltage or Current
Field Selectable Ranges

Full Isolation
18V Loop Supply
115VAC Standard
Opt. 230VAC, 9-30VDC
API 6380 G S
6380GS Ranges
6380GS Help
AC Voltage or Current (True RMS)
Field Selectable Ranges

DC Voltage or Current
Field Selectable Ranges

True RMS AC
Full Isolation
18V Loop Supply

115VAC Standard
Opt. 230VAC, 9-30VDC

  Strain Gauge/Bridge Input  Click Button For Details: 

Model Input Output

Additional Features

Power
API 1500 G Strain Gauge, Bridge, Load Cell
Specify Input Span
1 Field Adjustable Alarm
Specify Alarm Type
Adjustable Excitation  115VAC Standard
Opt. 230VAC, 9-30VDC
API 1520 G Strain Gauge, Bridge, Load Cell
Specify Input Span
2 Field Adjustable Alarms
Specify Alarm Type
Adjustable Excitation  115VAC Standard
Opt. 230VAC, 9-30VDC
API 4051 G Strain Gauge, Bridge, Load Cell
Specify Input Span

DC Voltage or Current
Specify Range

Adjustable Excitation  115VAC Standard
Opt. 230VAC, 9-30VDC
API 4058 G
4058G Ranges
4058G Help
1 to 4 Strain Gauges, Bridges, 
Load Cells
Field Selectable Ranges

DC Voltage or Current
Field Selectable Ranges

Adjustable Excitation  115VAC Standard
Opt. 230VAC, 9-30VDC
API 4059 G
4059G Help
4059G Ranges
1 to 4 Strain Gauges, Bridges, 
Load Cells
Field Selectable Ranges

DC Voltage or Current
Field Selectable Ranges

Full Isolation
Adjustable Excitation

 115VAC Standard
Opt. 230VAC, 9-30VDC
API SUM-xxx Summing Assembly Board for
1 to 4 Strain Gauges, Bridges, 
Load Cells

DC Voltage or Current
Use with 4058G or 4059G

Individually Adjustable
Excitation & Signal Trim
Optional SS Housing
 115VAC Standard
Opt. 230VAC, 9-30VDC

  Frequency Modules   Click Button For Details: 

Model Input Output Additional Features Power
API 1700 G 10 Hz to 20 KHz
Specify Input Span
1 Field Adjustable Alarm
Specify Alarm Type
   115VAC Standard
Opt. 230VAC, 9-30VDC
API 1720 G 10 Hz to 20 KHz
Specify Input Span
2 Field Adjustable Alarms
Specify Alarm Type
    115VAC Standard
Opt. 230VAC, 9-30VDC
API 7010 G 10 Hz to 20 KHz
Specify Input Span

DC Voltage or Current
Specify Range

Full Isolation  115VAC Standard
Opt. 230VAC, 9-30VDC
API 7500 G
7500G Ranges
7500G Help
DC Voltage or Current
Field Selectable Ranges

0-100 Hz to 0-30 KHz
Field Selectable
Specify Open Col. or TTL

Full Isolation
18V Loop Supply
  115VAC Standard
Opt. 230VAC, 9-30VDC
API 7500 G SS
7500SS Ranges
DC Voltage or Current
Field Selectable Ranges

0-1 Hz to 0-300 Hz
Field Selectable
Specify Open Col. or TTL

Full Isolation
18V Loop Supply
 115VAC Standard
Opt. 230VAC, 9-30VDC
API 7580 G
7580G Ranges
7580G Help
100 Hz to 30 KHz
Field Selectable Ranges

DC Voltage or Current
Field Selectable Ranges

Full Isolation
18V Loop Supply
 115VAC Standard
Opt. 230VAC, 9-30VDC

   Math Modules & Valve Positioner  Click Button For Details: 

Model Input Output Additional Features Power
API 4400 G thru
API 4408 G
Up to 4 DC Voltage or Current Inputs
Specify Ranges

DC Voltage or Current
Specify Range

Addition, Subtraction,
Averaging  Modules
 Isolated
 115VAC Standard
Opt. 230VAC, 9-30VDC
API 4440 G DC Voltage or Current
Specify Range

DC Voltage or Current
 Square Root of Input
Specify Range

Square Root Extraction
Full Isolation
18V Loop Supply

 115VAC Standard
Opt. 230VAC, 9-30VDC
API 3200 G DC Voltage or Current
Specify Range
100 ohm - 100 kohm Feedback Pot

2 SPST Relays

Valve / Actuator
Positioner / Controller
 115VAC Standard
Opt. 230VAC, 9-30VDC

  Loop Power Supplies  Click Button For Details: 

Model Input Output Additional Features Power
API 9046

115VAC Standard
Opt. 230VAC

Regulated DC Voltage
Specify 5 to 32 VDC

Isolated
Regulated

 115VAC Standard
Opt. 230VAC

API 9046 CH

115VAC Standard
Opt. 230VAC

Regulated DC Voltage
Bipolar (±) Output VDC
Specify ±5 to ±15 VDC

Isolated
Regulated

 115VAC Standard
Opt. 230VAC

  Module Accessories & Options  Click Button For Details: 

Power Options,
Sockets & Housings

Socket Data Sheet
8-Pin, 11-Pin Standard and Finger Safe Sockets

   Current Sensors  Click Button For Details: 

Model Input Output Additional Features Power
CTX-ACR
AC Current Transmitters
 0-2 Amps to 
 0-200 Amps AC
4-20 mA  True RMS
Isolated Output
Loop Powered
CTX-ACR-3S & 4S
High AC Current Transmitters
 0-375 Amps to 
 0-2000 Amps AC
4-20 mA  True RMS
Isolated Output
Loop Powered
CTX-DC
DC Current Transmitters
 0-50 Amps to
 0-400 Amps DC
4-20 mA Isolated Output 20-50 VDC or
 22-38VAC
CS-AC
AC Current Switches
 1.5-150 Amps AC 0.15 Amp SSR LED Status Indicator
NC or NO Models
Self Powered
CS-DC
DC Current Switches
 5-100 Amps DC 0.3 Amp SSR or
5 Amp Relay
LED Power Indicator
LED Status Indicator
20-28 VAC/DC or
12 VAC/DC
2RL/5RL/7RL/8RL
AC Current Transformers
 600 VAC 
 50:5 to 1600:5 Ratios
 Proportional to Input  24" Leads
4 Sizes
Self Powered

Tel: 1-800-794-5883
Fax: 1-800-830-7122
Absolute Process
Instruments, Inc.

Site Designed And Maintained By Panther Marketing And Design