| RTD
Input Alarm
RTD Input Transmitter |
Looptracker®
LEDs Push to Test Lifetime Warranty | ||||
| Model | Input | Output Ranges | Features | Data & Applications | Photo |
|
API 1400 G
RTD Input Single Alarm Trip Specify RTD Type, Temp. Range, Alarm Type, & Power
API 1420 G
| Factory
Configured 10 Ω to 2000Ω | 1 or 2 Field Adjustable 7A SPDT Alarm Relays | Hot-Swappable
Plug-In Design Looptracker® LEDs for Input Alarm Status LEDs Push to Test/Reset 2-Wire or 3-Wire RTD Lead Wire Compensation for 3-Wire Uses 11-Pin Socket |
Data Sheet | |
|
API 4000 G
Field Selectable Isolated RTD & T/C to DC Transmitter Specify Power | 13 Field
Settable T/C types J, T, E, R, S, Platinel II, Custom 10 Ω Copper 100 Ω 0.00385α 100 Ω 0.00391α 1000 Ω Ni-Fe 120 Ω Ni | 16 Field
Settable 0-1V to ±10V 0-2mA to 0-20mA 4-20mA | Minuteman
Setup Hot-Swappable Plug-In Design Microprocessor Linearization Looptracker® LED for Output Diagnostic LED Push to Test Full Isolation 2-Wire or 3-Wire RTD Lead Wire Compensation for 3-Wire Automatic Cold Junction Comp. T/C Upscale/Downscale Burnout Protection Uses 8-Pin Socket |
Data Sheet Range Settings Help Sheet | ![]() |
|
API 4001 G
Non-Isolated RTD-DC Transmitter Specify RTD Type, Temp. Range, Output & Power
API 4001 GL | Factory
Configured 10 Ω Copper 100 Ω 0.00385α 100 Ω 0.00391α 2000 Ω Ni-Fe Also available in °C -100-300°F 0-300°F 0-400°F 0-500°F 0-600°F 0-1000°F 0-1500°F | Factory
Configured Others available 0-1V 0-5V 1-5V 0-10 ±5V ±10V 0-20mA 4-20mA | Hot-Swappable
Plug-In Design Looptracker® LEDs for Input and Output Push to Test Full Isolation on 4001 GL 2-Wire or 3-Wire RTD Lead Wire Compensation for 3-Wire Optional Linearization on 4001G Uses 8-Pin Socket | Data Sheet |
|
|
API 4001 G SA-B
Non-Isolated Differential RTD-DC Transmitter Specify Temp. Range, Output & Power | Factory
Configured 100 Ω 0.00385α | Factory
Configured Others available 0-1V 0-5V 1-5V 0-10 ±5V ±10V 0-20mA 4-20mA | Hot-Swappable
Plug-In Design Looptracker® LEDs for Input and Output Push to Test 2-Wire or 3-Wire RTD Lead Wire Compensation for 3-Wire ΔT from 20F° to 900F° (10C° to 500C°) Linearized RTD Inputs Uses 11-Pin Socket | Data
Sheet Applications Monitor & Control Differential Temperature |
|
|
LP
200 Field Rangeable Loop-Powered Isolated RTD to DC Transmitter | 100 Ω
0.00385α 2 or 3 wire RTD | 4-20mA | Looptracker®
LED for Output Full Isolation RTD Linearization Push to Test |
Data Sheet Help Sheet | ![]() |
|