Chilled
Water Grille Diffuser AC Units - Standard Features
-
Maximum Design Flexibility
For both air cooled or water cooled applications.
Units designed for mounting above 2 ft. x 4 ft. suspended
panel opening. Provides comfort and temperature control
for many types of areas.
-
Coils
Copper tube, aluminum fin, mounted in a stainless
steel drain pan.
-
Compressor
Protected by thermal overload protection with both
high (manual reset) and low (automatic reset) pressure
switches. An expansion valve, a liquid line filter/dryer,
and a sight moisture indicator provide a completely
self-contained factory precharged refrigeration circuit.
-
Attractive 3-Way Supply Air Diffuser
And Return Air Grille
Shipped loose for "No Duct" units. Single
duct units only require a return air grille and double
units require neither.
-
Motors
3 Speed, long life motors for single phase operation.
-
Quick Clip Mounting Isolators
Mean fast and easy installation. Isolation is always
an important factor for noise.
-
Condensate Drain Pans
Stainless steel and elevated to allow for proper trapping
of condensate. Drain connections (3/4" f.p.t.)
are provided on each side of cabinet.
-
Float Switch
Provided for each drain pan to prevent overflow in
the event of a blocked drain line or if unit is not
installed in a level position. Switch is wired to
unit control panel.
-
Electrical Control Panel
Electrical Components to include: contactor (for AC
or WC units only), relay(s), control transformer and
power supply connections.
-
Fan(s)
Forward curved, direct drive for both supply fan and
condenser fan (air cooled units only).
-
Water Regulating Valve
Standard on water cooled units. Rated at 150 PSIG.
Optional
Features
-
Remote thermostat, wall mounted (can
be combined with 3 speed switch).
-
Low ambient control on air cooled units
-
Humidifier - evaporative media type
includes humidistat-remote wall-mounted.
-
Electric reheat (Hot water or steam
on request) with factory-wired contactor and remote
dehumidistat.
-
Remote condensate pump package
-
Transformer to 1-60-277 Volt.
-
Remote status panel w/L.E.D. indicators
for cooling, humidifying, condensate overflow.
-
Flow control with a 2-way solenoid valve
or a 3-way solenoid valve.
|
Model
|
Nominal CFM
|
Nominal Tons
|
Standard Horsepower
|
|
CWGD-1
|
400
|
1
|
1/4
|
|
CWGD-1.5
|
600
|
1.5
|
1/4
|
|
CWGD-2
|
800
|
2.0
|
1/4
|
T-Bar Air Conditioning
Units
T-Bar Air Conditioning
Units Installation & Maintenance Instructions
Air Cooled
- Grille Diffuser | Air
Cooled - Single Duct | Air
Cooled - Double Duct | Water
Cooled - Grille Diffuser
Water Cooled
- Single Duct | Water
Cooled - Double Duct | Chilled
Water - Grille Diffuser | DX
- Grille Diffuser
|