FNICO,Power Supplies,MTL,InstrumentsFNICO Power Supplies From MTL Instrument

  • Kentron Systems Index
  • About Kentron Systems
  • New Products
  • Manufacturers Represented
  • Contact Us

Process Controls Index

Process Controls Index

Kentron Systems Index

Kentron Systems Index

MTL Products



IS Digital Indicators

Fieldbus Displays

MTL660

MTL646/647

IS Barriers/Isolators

Intrinsic Safety Zener Barriers

MTL7700
MTL700
Intrinsic Safety Isolators
MTL2000
MTL4000
MTL4500
MTL5000
MTL5500
MTL (SR) Series
MTL E-Series
Configuration Tools & Software

Process I/O

Process I/O
HART Interfacing
MTL830

Surge Protection

Power Surge Protection
Data & Signal Surge Protection
Fieldbus
Telecoms

Fieldbus

Filedbus Power Supplies
Filedbus Wiring Components
Filedbus Diagnostics
Filedbus Test Equipment

Industrial Ethernet

Industrial Ethernet

Other Manufacturers

Kentron Systems Index

Expo Technologies

Fluenta

Hobré Instruments

MPM Flowmeter

MTL Instrument

ProAnalysis

Sensorlink

Sentech AS

Siemens

Related Web Sites

www.kentron.ca

FNICO,Power Supplies,MTL,InstrumentsFor applications in Zone 2 and Division 2 hazardous areas, MTL’s Fieldbus Non-Incendive Concept (FNICO) brings the benefits of FISCO together with higher current levels, allowing yet more devices per trunk. Live-working is permissible without gas clearance, allowing devices to be connected or removed while under power. MTL FNICO supplies 9111-NI (IIC/Group A) and 9112-NI (IIB/Group C, D) repeat the H1/Profibus-PA signal as a non-incendive bus for connection to suitably approved field instruments in Zone 2 or Division 2. For easy integration of FNICO power supplies with DCS Fieldbus Interface Modules (FIMs), MTL supply Termination Boards that use the DCS client system interconnect cables. The boards support upto four power supplies and feature built-in segment terminators. Users wanting to connect to entity-only certified devices please refer to our spur connector range.

 

FNICO Power Supplies Literature

 

Product Code Description Downloads
9111-NI9111-NI is intrinsically safe FNICO power supply ~ IIC Datasheet 
9112-NI9112-NI is intrinsically safe FNICO power supply ~ IIB Datasheet 
Overview of FNICO power supplies Datasheet 
F606 Redundant / non-redundant 4-segment Termination Board for use with Yokogawa ALF-111 Fieldbus Communi Datasheet 
F656A Non-redundant 2-segment Remote Termination Panel for use with Honeywell Experion PKS Fieldbus Datasheet 

 

  • MTL Instrument |
  • Fluenta |
  • Sentech AS |
  • Siemens |
  • MPM |
  • Expo Technologies | Designed By Panther Marketing & Design