    Flow Measurement Technology
    PVC Positive Displacement Flow Meter
PVC Positive Displacement Flow Meter
Sizes and Flow Ranges:


PVC Multipulse Flow Meter

Size
Flow Range
25mm
(1")
120~3000 L/hr
(32~790 gal/hr)

PVC Positive Displacement Flow Meter Material:
  • UPVC body and manifold
  • Carbon filled teflon piston and bearing (UV stabilised PVC)
  • Special material contact us
PVC Positive Displacement Flow Meter Specifications:

Cut-away showing flow through meter

Process Connections: Threaded BSPP female thread.
Pressure Rating: 4 bar
Temperature Rating: 40°C
(100°F)
Multipulse Outputs: Both reed switch & NPN open collector outputs* are standard.

Two Pulse Outputs

Two Pulse Outputs (standard)
1. Reed Switch Output
Provides a voltage free contact closure. The reed switch is classed as a "simple device" and can be used in hazardous areas when connected via an approved intrinsically safe barrier.

2. Square Wave Output

An open collector pulse output produced by a solid state hall effect device. This three wire device requires 5~24Vdc excitation voltage and produces a high resolution square wave output.


Options
  • Explosion Proof terminal housing
  • Integral or remote high speed preset batch controller
  • Integral or remote battery powered flow rate totaliser with scaled pulse output, analog and flow alarm outputs
Typical Applications

Flow Meter With Rate Totaliser
  • Trimec's MP025 one inche Positive Displacement Flow Meter manufactured from UV stabilised PVC (UPVC) is ideally suited for special applications associated with corrosive fluid such as sodium hypochlorite, acids, photographic solutions or any chemical compatible with UPVC.
  • The MP025 has a flow range of 12-~300 L/hr and provides an economical solution for those difficult fluids compared to more expensive magnetic flow meters or Coriollis mas flowmeters manufactured from more exotic materials.

Multipulse Positive Displacement Flow Meter Styles:

Stainless | Aluminum | High Pressure | Hygenic | PVC | Trimec