Over,The,Side,Immersion,Heaters

Over The Side Immersion
Heaters

    Index| About Us | Products | New Products | Contact Us

ASB Heating Products

Band Heaters
  Band Heaters Introduction
 
Aluminum Flex Band Heaters
  Ceramic Band Heaters
  Mica Band Heaters
  Mineral Insulated Band
Heater

CalRod® Heaters

  See Tubular Heaters

Cartridge Heaters

  Cartridge Heaters Introduction
 
Lead Configurations
  Metric Diameters
  c/w Immersion Fittings
  c/w Built-In Thermocouple


Drum Heaters

  Direct Immersion Heaters
  Mica Band Heaters
  Silicone Rubber Band Heaters

Duct Heaters
  Duct Heaters
  Medium Temperature
  up to 400ºC (750ºF)
  High Temperature
  up to 560ºC (1040ºF)


Finned Tubular Elements
  See Tubular Elements

Immersion Heaters
  Immersion Heaters Introduction
  Circulation Heater
  Dry Well Heater
  Flange Heater
  Indirect Heater
  Over The Side Heater
  Pipe Insert Heater
  Screw Plug Heater


Mould Heaters
  Tubular Heaters
  Formed to AutoCAD Drawings


Radiant Heaters
  Black Body
  CalRod®
  Ceramic Emitters
  Glass Ceramic Face
  Infrared
  Metal Sheathed Tubular
  Quartz Lamp
  Ribbon Desing
  Vycor Quartz Face


Silicone Rubber Heaters
  Adhesive Backed
  Built-In Thermostats


Strip Heaters
  High Density Strip Heaters
  Mica Strip Heaters
  Mineral Insulated Strip Heaters


Tank Heaters
  See Drum Heaters
  See Immersion Heaters
  See Strip Heaters
  See Tubular Elements


Temperature Controllers
  Bulb and Capillary Controls
  Analog Temp. Controls
  Microprocessor Temp. Controls
  1/16 DIN Temp. Controls
  1/32 DIN Temp. Controls
  1/4, 1/8 DIN Temp. Controls
  Mercury Relays
  Solid State Relays

Thermocouples
  Accessories
  Adjustable Bayonet

  Mineral Insulated
  Nozzle & Pipe Clamp
  Plugs and Jacks
  Ring Tongue & Shimstock
  RTD Sensors
  Terminations
  Tube & Wire


Tubular Heaters
  Finned Tubular Heaters
  Formed Tubular Heaters
  Formed to AutoCAD Drawings
  Mechanical Fittings
  Straight Tubular Heaters

  Tubular Heating Elements

Technical Data

  Heat Loss Data
  What ASB Needs To Know
  Unique Heater Pictures
 

Useful Web Site Tools
To request product information at anytime click below.



www.asbheat.com
  Over The Side Immersion Heaters

Over The Side Immersion Heaters - All applications must consider the suitability of the sheath material, the correct watt density, the mounting method to fit into the tank, available length along the tank bottom, the riser height, size of the tank opening and appropriate terminal enclosure.

Call ASB Heating Elements Limited for Technical Assistance: 1-800-265-9699

Over The Side Immersion Heaters

Over The Side Immersion Heaters come in a wide variety of configurations, styles, and shapes. Our goal is create a simple yet effective design to solve any fluid-heating environment you have. By selecting the best sheath material, choosing the optimum fitting method and manufacturing the elements to any desired watt density you can expect the optimum engineered heating solution for your requirements.

Fast delivery gets you this perfect heater almost immediately.

Over The Side Immersion Heaters

  • used when an immersion heater cannot be installed into a tank fitting or
  • when heater removal without draining the tank is vital
  • these heaters are lowered into the liquid from the top
  • can have very long vertical risers for power connections to be made at the
    top of the tank, heaters with a 45 foot vertical risers have been installed
  • there is no heat generated in the vertical riser
  • general purpose terminal enclosure (NEMA 1), weather resistant terminal enclosure (NEMA 4), and hazardous location terminal enclosure (NEMA 7), available
  • thermocouples, thermostats, and high limit controls can be built-in

Most Common Sheath Material

  • copper
  • steel
  • stainless steel
  • Incoloy 800®
  • Inconel 600®
  • titanium
  • Other sheath material also offered

Most Common Terminal Enclosures

  • General Purpose NEMA1
  • Weather Resistant NEMA 4, NEMA 4X
  • Hazardous Location NEMA 7

Most Common Sheath Materials, Application, and Watt Densities

Sheath Material
Application
Watt Density
Watt.in2
Copper
To heat potable water
40-72
Steel
Oil
20-25
Hydraulic oil
12-15
Stainless Steel
Process water, mild acid, de-ionized water
20-60
Incoloy 800®
Water, mild alkaline solutions, air and gases maximum sheath temperature 1400ºF
10-125
Incoloy 600®
Water, very alkaline solutions, high temperature air and gases
Maximum sheath temperature 1500ºF
10-50

Most common built-in control Options

  • "K" calibrated thermocouple for high limit sheath protection
  • "J" calibrated thermocouple for temperature control
  • mechanical thermostats:

Power Ratings

  • up to 240 volts, 25-amp single pole, single throw (SPST)
  • up to 240 volts, 25-amp double pole, single throw (DPST)
  • up to 600 volts, 15-amp triple pole, single throw (TPST)

Temperature Ranges

  • -16 to 40°C (0-100°F)
  • 10 to120°C (50-250°F)
  • 70 to 280°C (160-540°F)
  • 160 to 370°C (320-700°F)


   

    Index| About Us | Products | New Products | Contact Us