Duct Heater -
All applications must consider the airflow velocity, the desired
outlet temperature, the correct watt density, and the mounting
support.
Call
ASB Heating Elements Limited for Technical Assistance: 1-800-265-9699
Duct
Heater
Forced Air Duct Heater - for
Industrial Process Heating Only
Ovens often require re-circulated
air, or forced circulation, to perform the desired heating task.
A duct heater mounted in this re-circulated air stream is an
effective way to provide this heat, without having any electrical
connections inside your oven.
Typical
Applications
- heat treating, up to1000°F
(540°C)
- curing
- baking
- drying
- batch heating
- conveyor systems
Typical Air
Heat Calculation
| kW = |
SCFM
x temperature rise
3000
|
kW - kilowatts
SCFM - standard cubic feet per minute
Temperature rise - number of degrees Fahrenheit increase required
A 20% safety factor is highly